Please use this identifier to cite or link to this item:
https://hdl.handle.net/2445/222193
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Belle II VTX Collaboration | - |
dc.contributor.author | Belle II VTX Upgrade Group | - |
dc.contributor.author | Alonso Casanovas, Oscar | - |
dc.contributor.author | Dieguez Barrientos, Angel | - |
dc.date.accessioned | 2025-07-14T08:22:33Z | - |
dc.date.issued | 2024-07 | - |
dc.identifier.issn | 0168-9002 | - |
dc.identifier.uri | https://hdl.handle.net/2445/222193 | - |
dc.description.abstract | The Belle II experiment at KEK in Japan considers an upgrade for the vertex detector system in line with the accelerator upgrade for higher luminosity at long shutdown 2 planned for 2028. One proposal for the upgrade of the vertex detector called VTX aims to improve background robustness and reduce occupancy using small and fast pixels. VTX accommodates the OBELIX depleted monolithic active CMOS pixel sensor (DMAPS) on all five proposed layers. OBELIX is specifically developed for the VTX application and based on the TJ-Monopix2 chip initially developed to meet the requirements of the outer layers of the ATLAS inner tracker (ITk). This paper will review recent tests of the TJ-Monopix2 chip as well as various design aspects of the OBELIX-1 chip currently under development. | - |
dc.format.extent | 7 p. | - |
dc.format.mimetype | application/pdf | - |
dc.language.iso | eng | - |
dc.publisher | Elsevier B.V. | - |
dc.relation.isformatof | Versió postprint del document publicat a: https://doi.org/10.1016/j.nima.2024.169428 | - |
dc.relation.ispartof | Nuclear Instruments & Methods in Physics Research Section A-Accelerators Spectrometers Detectors and Associated Equipment, 2024, vol. 1064 | - |
dc.relation.uri | https://doi.org/10.1016/j.nima.2024.169428 | - |
dc.rights | cc-by-nc-nd (c) Elsevier B.V., 2024 | - |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | - |
dc.source | Articles publicats en revistes (Enginyeria Electrònica i Biomèdica) | - |
dc.subject.classification | Detectors | - |
dc.subject.classification | Mesuraments físics | - |
dc.subject.other | Detectors | - |
dc.subject.other | Physical measurements | - |
dc.title | The DMAPS upgrade of the Belle II vertex detector | - |
dc.type | info:eu-repo/semantics/article | - |
dc.type | info:eu-repo/semantics/acceptedVersion | - |
dc.identifier.idgrec | 754557 | - |
dc.date.updated | 2025-07-14T08:22:34Z | - |
dc.rights.accessRights | info:eu-repo/semantics/embargoedAccess | - |
dc.embargo.lift | 2026-06-30 | - |
dc.date.embargoEndDate | info:eu-repo/date/embargoEnd/2026-06-30 | - |
Appears in Collections: | Articles publicats en revistes (Enginyeria Electrònica i Biomèdica) |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
879400.pdf | 2.48 MB | Adobe PDF | View/Open Request a copy |
Document embargat fins el
30-6-2026
This item is licensed under a
Creative Commons License