Please use this identifier to cite or link to this item: https://hdl.handle.net/2445/222283
Full metadata record
DC FieldValueLanguage
dc.contributor.authorVicente Rabaneda, Esther F.-
dc.contributor.authorMöller, Ingrid-
dc.contributor.authorMata, Abdon-
dc.contributor.authorMontes, Nuria-
dc.contributor.authorRodríguez Vargas, Gabriel Santiago-
dc.contributor.authorCoronel Tarancón, Luis-
dc.contributor.authorBong, David A.-
dc.contributor.authorCastañeda, Santos-
dc.contributor.authorSantos Moreno, Pedro-
dc.date.accessioned2025-07-16T09:30:44Z-
dc.date.available2025-07-16T09:30:44Z-
dc.date.issued2025-05-25-
dc.identifier.issn2077-0383-
dc.identifier.urihttps://hdl.handle.net/2445/222283-
dc.description.abstractBackground/Objectives: The objective of this study is to investigate the intra- and inter-explorer reliability of different lung ultrasound (LUS) scores in patients with suspected rheumatoid arthritis with associated interstitial lung disease (RA-ILD). Methods: Fourteen consecutive patients with suspected RA-ILD based on the presence of respiratory symptoms, lung function tests (LFTs) or imaging alterations were recruited. The screening protocol consisted of an LFT, a chest X-ray, and HRCT. LUS examinations of different B-line and pleural line scores including 14 intercostal spaces were performed by three experienced sonographers, guaranteeing blinding. Intra- and inter-explorer reliability were calculated for all LUS scores and at the intercostal space level by weighted Cohen's kappa and Fleiss' kappa, respectively, relying on absolute differences using Stata/IC 14.2 software (R) (StataCorp, College Station, TX, USA). Results: Both global (& kgreen; = 0.73-0.82) and binary (& kgreen; = 0.80-0.90) scores of B lines showed substantial to excellent intra-explorer reliability, with slightly better results for the binary score. The inter-explorer reliability was equally excellent for the global score (& kgreen; = 0.93) and the binary score (& kgreen; = 0.90) of B lines. The intra-explorer reliability of the semiquantitative pleural score was excellent for all the sonographers (& kgreen; = 0.88-0.91), and the binary pleural score had slightly lower intra-explorer reliability (& kgreen; = 0.77-0.84). Regarding inter-explorer reliability, both semiquantitative and binary pleural scores were equally excellent (& kgreen; = 0.84). Good to excellent inter-explorer reliability was found in all the scanned areas. Conclusions: Substantial to excellent intra- and inter-explorer reliability of different feasible B-line and pleural LUS scores were found, adding evidence in favor of the potential implementation of LUS for RA-ILD diagnosis in clinical practice.-
dc.format.extent20 p.-
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherMDPI-
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.3390/jcm14113701-
dc.relation.ispartofJournal of Clinical Medicine, 2025, vol. 14, num. 11, 3701-
dc.relation.urihttps://doi.org/10.3390/jcm14113701-
dc.rightscc-by (c) Vicente Rabaneda, Esther F. et al., 2025-
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.sourceArticles publicats en revistes (Institut d'lnvestigació Biomèdica de Bellvitge (IDIBELL))-
dc.subject.classificationArtritis reumatoide-
dc.subject.classificationDiagnòstic per la imatge-
dc.subject.otherRheumatoid arthritis-
dc.subject.otherDiagnostic imaging-
dc.titleA proposal for a new lung ultrasound score in rheumatoid arthritis: the reliability of lung ultrasound for rheumatoid arthritis-associated interstitial lung disease diagnosis-
dc.typeinfo:eu-repo/semantics/article-
dc.typeinfo:eu-repo/semantics/publishedVersion-
dc.date.updated2025-07-15T07:51:20Z-
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
dc.identifier.pmid40507462-
Appears in Collections:Articles publicats en revistes (Institut d'lnvestigació Biomèdica de Bellvitge (IDIBELL))

Files in This Item:
File Description SizeFormat 
jcm-14-03701.pdf802.99 kBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons