Please use this identifier to cite or link to this item:
https://hdl.handle.net/2445/54003| Title: | Dynamic range extension of SiPM detectors with the time-gated operation |
| Author: | Vilella Figueras, Eva Diéguez Barrientos, Àngel |
| Keywords: | Detectors de radiació Metall-òxid-semiconductors complementaris Optoelectrònica Detectors òptics Nuclear counters Complementary metal oxide semiconductors Optoelectronics Optical detectors |
| Issue Date: | 12-May-2014 |
| Publisher: | Optical Society of America |
| Abstract: | The silicon photomultiplier (SiPM) is a novel detector technology that has undergone a fast development in the last few years, owing to its single-photon resolution and ultra-fast response time. However, the typical high dark count rates of the sensor may prevent the detection of low intensity radiation fluxes. In this article, the time-gated operation with short active periods in the nanosecond range is proposed as a solution to reduce the number of cells fired due to noise and thus increase the dynamic range. The technique is aimed at application fields that function under a trigger command, such as gated fluorescence lifetime imaging microscopy. |
| Note: | Reproducció del document publicat a: http://dx.doi.org/10.1364/OE.22.012007 |
| It is part of: | Optics Express, 2014, vol. 22, num. 10, p. 12007-12012 |
| URI: | https://hdl.handle.net/2445/54003 |
| Related resource: | http://dx.doi.org/10.1364/OE.22.012007 |
| ISSN: | 1094-4087 |
| Appears in Collections: | Articles publicats en revistes (Enginyeria Electrònica i Biomèdica) |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| 641236.pdf | 974.12 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.