Please use this identifier to cite or link to this item: http://hdl.handle.net/2445/8544
Full metadata record
DC FieldValueLanguage
dc.contributor.authorLlacer, Jorgecat
dc.contributor.authorVeklerov, Eugenecat
dc.contributor.authorCoakley, Kevin J.cat
dc.contributor.authorHoffman, Edward J.cat
dc.contributor.authorNúñez de Murga, Jorge, 1955-cat
dc.date.accessioned2009-06-08T08:58:01Z-
dc.date.available2009-06-08T08:58:01Z-
dc.date.issued1993cat
dc.identifier.issn0278-0062cat
dc.identifier.urihttp://hdl.handle.net/2445/8544-
dc.description.abstractThe work presented evaluates the statistical characteristics of regional bias and expected error in reconstructions of real positron emission tomography (PET) data of human brain fluoro-deoxiglucose (FDG) studies carried out by the maximum likelihood estimator (MLE) method with a robust stopping rule, and compares them with the results of filtered backprojection (FBP) reconstructions and with the method of sieves. The task of evaluating radioisotope uptake in regions-of-interest (ROIs) is investigated. An assessment of bias and variance in uptake measurements is carried out with simulated data. Then, by using three different transition matrices with different degrees of accuracy and a components of variance model for statistical analysis, it is shown that the characteristics obtained from real human FDG brain data are consistent with the results of the simulation studies.eng
dc.format.extent17 p.cat
dc.format.mimetypeapplication/pdfeng
dc.language.isoengeng
dc.publisherIEEEcat
dc.relation.isformatofReproducció del document publicat a http://dx.doi.org/10.1109/42.232250cat
dc.relation.ispartofIEEE Transactions on Medical Imaging, 1993, vol. 12, núm. 2, p. 215-231.cat
dc.relation.urihttp://dx.doi.org/10.1109/42.232250-
dc.rights(c) IEEE, 1993cat
dc.sourceArticles publicats en revistes (Física Quàntica i Astrofísica)-
dc.subject.classificationCervellcat
dc.subject.classificationTomografia d'emissiócat
dc.subject.classificationEstadísticacat
dc.subject.otherBraineng
dc.subject.otherComputerised tomographyeng
dc.subject.otherRadioisotope scanning and imagingeng
dc.subject.otherStatistical analysiseng
dc.titleStatistical analysis of maximum likelihood estimator images of human brain FDG PET studieseng
dc.typeinfo:eu-repo/semantics/articleeng
dc.typeinfo:eu-repo/semantics/publishedVersion-
dc.identifier.idgrec500837cat
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
Appears in Collections:Articles publicats en revistes (Física Quàntica i Astrofísica)

Files in This Item:
File Description SizeFormat 
500837.pdf1.85 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.