Please use this identifier to cite or link to this item: https://hdl.handle.net/2445/99019
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPurrà, Miquel-
dc.contributor.authorCinca, Roser-
dc.contributor.authorLegaz, Jessica-
dc.contributor.authorNúñez Burcio, Oscar-
dc.date.accessioned2016-05-30T10:45:48Z-
dc.date.available2016-05-30T10:45:48Z-
dc.date.issued2014-08-22-
dc.identifier.issn1618-2642-
dc.identifier.urihttps://hdl.handle.net/2445/99019-
dc.description.abstractA field amplified sample injection-capillary zone electrophoresis (FASI-CZE) method for the analysis of benzophenone (BP) UV-filters in environmental water samples was developed, allowing the separation of all compounds in less than 8 minutes. A 9- to 25-fold sensitive enhancement was obtained with FASI-CZE, achieving limits of detection down to 21-59 µg/L for most of the analyzed BPs, with acceptable run-to-run and day-to-day precisions (relative standard deviations lower than 17%). In order to remove water sample salinity and to enhance FASI sensitivity, an off-line solid-phase extraction (SPE) procedure using a Strata X polymeric reversed-phase sorbent was proposed, obtaining recoveries up to 72-90% for most of benzophenones. With the combination of off-line SPE and FASI-CZE, limits of detection in the range 0.06-0.6 µg/L in a river water matrix, representing a 2400- to 6500-fold enhancement, were obtained. Method performance was evaluated by quantifying a blank river water sample spiked at 1 µg/L. For a 95% confidence level, no statistical differences were observed between found concentrations and spiked concentrations (probability at the confidence level, p value, of 0.60), showing that the proposed off-line SPE-FASI-CZE method is suitable for the analysis of benzophenone UV-filters in environmental water samples at low µg/L levels. The method was successfully applied to the analysis of BPs in river water samples collected before and after industrialized and urban areas, and in some drinking water samples.-
dc.format.extent14 p.-
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherSpringer Verlag-
dc.relation.isformatofVersió postprint del document publicat a: http://dx.doi.org/10.1007/s00216-014-8086-z-
dc.relation.ispartofAnalytical and Bioanalytical Chemistry, 2014, vol. 406, num. 25, p. 6189-6202-
dc.relation.urihttp://dx.doi.org/10.1007/s00216-014-8086-z-
dc.rights(c) Springer Verlag, 2014-
dc.sourceArticles publicats en revistes (Enginyeria Química i Química Analítica)-
dc.subject.classificationAnàlisi de l'aigua-
dc.subject.classificationElectroforesi capil·lar-
dc.subject.otherWater analysis-
dc.subject.otherCapillary electrophoresis-
dc.titleSolid-phase extraction and field-amplified sample injection-capillary zone electrophoresis for the analysis of benzophenone UV-filters in environmental water samples-
dc.typeinfo:eu-repo/semantics/article-
dc.typeinfo:eu-repo/semantics/acceptedVersion-
dc.identifier.idgrec642831-
dc.date.updated2016-05-30T10:45:53Z-
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
dc.identifier.pmid25146354-
Appears in Collections:Articles publicats en revistes (Enginyeria Química i Química Analítica)

Files in This Item:
File Description SizeFormat 
642831.pdf944.83 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.