Barceló, CristianSerrano i Plana, NúriaAriño Blasco, CristinaDíaz Cruz, José ManuelEsteban i Cortada, Miquel2019-09-052019-09-052015-10-281040-0397https://hdl.handle.net/2445/139347An Ex-situ antimony film screen-printed carbon electrode (Ex-situ SbSPCE) was successfully applied for the determination of Ni(II), by means of adsorptive stripping voltammetry using dimethylglyoxime as complexing agent, in a certified reference wastewater sample. This electrode is proposed as an alternative to more conventional antimony film electrodes. Ex-situ SbSPCE was analytically characterized and the obtained parameters suggest that Ex-situ SbSPCE behaves much better than both Ex-situ BiSPCE and BispSPE for Ni(II) determination. The results confirm the applicability of Ex-situ SbSPCE for the determination of low concentration levels of Ni(II) in natural samples with a very high reproducibility and good trueness.5 p.application/pdfeng(c) Wiley-VCH, 2015NíquelVoltametriaAnàlisi electroquímicaNickelVoltammetryElectrochemical analysisEx-situ antimony screen-printed carbon electrode for voltammetric determination of Ni(II) - ions in wastewaterinfo:eu-repo/semantics/article6546862019-09-05info:eu-repo/semantics/openAccess