Please use this identifier to cite or link to this item: http://hdl.handle.net/2445/113498
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMartínez Lacasa, Daniel-
dc.contributor.authorMoreno Blanc, Javier-
dc.contributor.authorTresanchez, Marcel-
dc.contributor.authorClotet Bellmunt, Eduard-
dc.contributor.authorJiménez-Soto, Juan M.-
dc.contributor.authorMagrans, Rudys-
dc.contributor.authorPardo Martínez, Antonio-
dc.contributor.authorMarco Colás, Santiago-
dc.contributor.authorPalacín Roca, Jordi-
dc.date.accessioned2017-07-07T12:46:29Z-
dc.date.available2017-07-07T12:46:29Z-
dc.date.issued2016-01-24-
dc.identifier.issn1687-725X-
dc.identifier.urihttp://hdl.handle.net/2445/113498-
dc.description.abstractThis paper presents the measurement of gas concentration and wind intensity performed with a mobile robot in a custom turbulent wind tunnel designed for experimentation with customizable wind and gas leak sources. This paper presents the representation in different information layers of the measurements obtained in the turbulent wind tunnel under different controlled environmental conditions in order to describe the plume of the gas and wind intensities inside the experimentation chamber. The information layers have been generated from the measurements gathered by individual onboard gas and wind sensors carried out by an autonomous mobile robot. On the one hand, the assumption was that the size and cost of these specialized sensors do not allow the creation of a net of sensors or other measurement alternatives based on the simultaneous use of several sensors, and on the other hand, the assumption is that the information layers created will have application on the development and test of automatic gas source location procedures based on reactive or nonreactive algorithms.-
dc.format.extent8 p.-
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherHindawi-
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.1155/2016/7184980-
dc.relation.ispartofJournal of Sensors, 2016, vol. 2016, p. 7184980-
dc.relation.urihttps://doi.org/10.1155/2016/7184980-
dc.rightscc-by (c) Martínez Lacasa, Daniel et al., 2016-
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es-
dc.sourceArticles publicats en revistes (Enginyeria Electrònica i Biomèdica)-
dc.subject.classificationRobòtica-
dc.subject.classificationGas-
dc.subject.classificationVents-
dc.subject.classificationDetectors-
dc.subject.classificationMesurament-
dc.subject.otherRobotics-
dc.subject.otherGas-
dc.subject.otherWinds-
dc.subject.otherDetectors-
dc.subject.otherMensuration-
dc.titleMeasuring gas concentration and wind intensity in a turbulent wind tunnel with a mobile robot-
dc.typeinfo:eu-repo/semantics/article-
dc.typeinfo:eu-repo/semantics/publishedVersion-
dc.identifier.idgrec660183-
dc.date.updated2017-07-07T12:46:29Z-
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
Appears in Collections:Articles publicats en revistes (Enginyeria Electrònica i Biomèdica)

Files in This Item:
File Description SizeFormat 
660183.pdf4.54 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons