Please use this identifier to cite or link to this item: http://hdl.handle.net/2445/141577
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMartínez, Dominique-
dc.contributor.authorBurgués, Javier-
dc.contributor.authorMarco Colás, Santiago-
dc.date.accessioned2019-10-02T15:39:28Z-
dc.date.available2019-10-02T15:39:28Z-
dc.date.issued2019-09-18-
dc.identifier.issn1424-8220-
dc.identifier.urihttp://hdl.handle.net/2445/141577-
dc.description.abstractMetal oxide (MOX) sensors are widely used for chemical sensing due to their low cost, miniaturization, low power consumption and durability. Yet, getting instantaneous measurements of fluctuating gas concentration in turbulent plumes is not possible due to their slow response time. In this paper, we show that the slow response of MOX sensors can be compensated by deconvolution, provided that an invertible, parametrized, sensor model is available. We consider a nonlinear, first-order dynamic model that is mathematically tractable for MOX identification and deconvolution. By transforming the sensor signal in the log-domain, the system becomes linear in the parameters and these can be estimated by the least-squares techniques. Moreover, we use the MOX diversity in a sensor array to avoid training with a supervised signal. The information provided by two (or more) sensors, exposed to the same flow but responding with different dynamics, is exploited to recover the ground truth signal (gas input). This approach is known as blind deconvolution. We demonstrate its efficiency on MOX sensors recorded in turbulent plumes. The reconstructed signal is similar to the one obtained with a fast photo-ionization detector (PID). The technique is thus relevant to track a fast-changing gas concentration with MOX sensors, resulting in a compensated response time comparable to that of a PID.-
dc.format.extent16 p.-
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherMDPI-
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.3390/s19184029-
dc.relation.ispartofSensors, 2019, vol. 19, num. 18, p. 4029-4044-
dc.relation.urihttps://doi.org/10.3390/s19184029-
dc.rightscc-by (c) Martínez, Dominique et al., 2019-
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es-
dc.sourceArticles publicats en revistes (Enginyeria Electrònica i Biomèdica)-
dc.subject.classificationMetall-òxid-semiconductors-
dc.subject.classificationDetectors de gasos-
dc.subject.otherMetal oxide semiconductors-
dc.subject.otherGas detectors-
dc.titleFast measurements with MOX sensors: A least-squares approach to blind deconvolution-
dc.typeinfo:eu-repo/semantics/article-
dc.typeinfo:eu-repo/semantics/publishedVersion-
dc.identifier.idgrec691697-
dc.date.updated2019-10-02T15:39:29Z-
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
dc.identifier.pmid31540524-
Appears in Collections:Articles publicats en revistes (Enginyeria Electrònica i Biomèdica)

Files in This Item:
File Description SizeFormat 
691697.pdf2.33 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons