Please use this identifier to cite or link to this item: http://hdl.handle.net/2445/16082
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPadilla, Martacat
dc.contributor.authorPerera Lluna, Alexandrecat
dc.contributor.authorMontoliu, I.cat
dc.contributor.authorChaudry, A.cat
dc.contributor.authorPersaud, K.cat
dc.contributor.authorMarco Colás, Santiagocat
dc.date.accessioned2011-02-09T09:59:52Z-
dc.date.available2011-02-09T09:59:52Z-
dc.date.issued2010-01-15-
dc.identifier.issn0169-7439-
dc.identifier.urihttp://hdl.handle.net/2445/16082-
dc.description.abstractDrift is an important issue that impairs the reliability of gas sensing systems. Sensor aging, memory effects and environmental disturbances produce shifts in sensor responses that make initial statistical models for gas or odor recognition useless after a relatively short period (typically few weeks). Frequent recalibrations are needed to preserve system accuracy. However, when recalibrations involve numerous samples they become expensive and laborious. An interesting and lower cost alternative is drift counteraction by signal processing techniques. Orthogonal Signal Correction (OSC) is proposed for drift compensation in chemical sensor arrays. The performance of OSC is also compared with Component Correction (CC). A simple classification algorithm has been employed for assessing the performance of the algorithms on a dataset composed by measurements of three analytes using an array of seventeen conductive polymer gas sensors over a ten month period.eng
dc.format.extent26 p.-
dc.format.mimetypeapplication/pdf-
dc.language.isoengeng
dc.publisherElsevier B.V.-
dc.relation.isformatofVersió postprint del document publicat a: http://dx.doi.org/10.1016/j.chemolab.2009.10.002cat
dc.relation.ispartofChemometrics and Intelligent Laboratory Systems, 2010, vol. 100, núm. 1, p. 28-35-
dc.relation.urihttp://dx.doi.org/10.1016/j.chemolab.2009.10.002-
dc.rights(c) Elsevier B.V. , 2009-
dc.sourceArticles publicats en revistes (Enginyeria Electrònica i Biomèdica)-
dc.subject.classificationDetectors de gasoscat
dc.subject.otherGas detectorseng
dc.titleDrift compensation of gas sensor array data by Orthogonal Signal Correctioneng
dc.typeinfo:eu-repo/semantics/article-
dc.typeinfo:eu-repo/semantics/acceptedVersion-
dc.identifier.idgrec596219-
dc.relation.projectIDinfo:eu-repo/grantAgreement/EC/FP7/216916/EU//NEUROCHEM-
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
Appears in Collections:Articles publicats en revistes (Enginyeria Electrònica i Biomèdica)
Publicacions de projectes de recerca finançats per la UE

Files in This Item:
File Description SizeFormat 
596219.pdf958.04 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.