Please use this identifier to cite or link to this item: http://hdl.handle.net/2445/182131
Full metadata record
DC FieldValueLanguage
dc.contributor.authorDulay, Samuel-
dc.contributor.authorRivas, Lourdes-
dc.contributor.authorPla, Laura-
dc.contributor.authorBerdún Marin, Sergio-
dc.contributor.authorEixarch Roca, Elisenda-
dc.contributor.authorGratacós Solsona, Eduard-
dc.contributor.authorIlla Armengol, Míriam-
dc.contributor.authorMir Llorente, Mònica-
dc.contributor.authorSamitier i Martí, Josep-
dc.date.accessioned2022-01-04T14:21:08Z-
dc.date.available2022-01-04T14:21:08Z-
dc.date.issued2021-12-20-
dc.identifier.issn1754-1611-
dc.identifier.urihttp://hdl.handle.net/2445/182131-
dc.description.abstractUnder intrauterine growth restriction (IUGR), abnormal attainment of the nutrients and oxygen by the fetus restricts the normal evolution of the prenatal causing in many cases high morbidity being one of the top-ten causes of neonatal death. The current gold standards in hospitals to detect this relevant problem is the clinical observation by echography, cardiotocography and Doppler. These qualitative techniques are not conclusive and requires risky invasive fetal scalp blood testing and/or amniocentesis. We developed micro-implantable multiparametric electrochemical sensors for measuring ischemia in real time in fetal tissue and vascular. This implantable technology is designed to continuous monitoring for an early detection of ischemia to avoid potential fetal injury. Two miniaturized electrochemical sensors were developed based on oxygen and pH detection. The sensors were optimized in vitro under controlled concentration, to assess the selectivity and sensitivity required. The sensors were then validated in vivo in the ewe fetus model, by means of their insertion in the muscle leg and inside the iliac artery of the fetus. Ischemia was achieved by gradually obstructing the umbilical cord to regulate the amount of blood reaching the fetus. An important challenge in fetal monitoring is the detection of low levels of oxygen and pH changes under ischemic conditions, requiring high sensitivity sensors. Significant differences were observed in both; pH and pO2 sensors under changes from normoxia to hypoxia states in the fetus tissue and vascular with both sensors. Herein, we demonstrate the feasibility of the developed sensors for future fetal monitoring in medical applications.-
dc.format.extent11 p.-
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.1186/s13036-021-00280-7-
dc.relation.ispartofJournal Of Biological Engineering, 2021, num. 15-
dc.relation.urihttps://doi.org/10.1186/s13036-021-00280-7-
dc.rightscc by (c) Dulay, Samuel et al, 2021-
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.sourceArticles publicats en revistes (Enginyeria Electrònica i Biomèdica)-
dc.subject.classificationMonitoratge fetal-
dc.subject.classificationIsquèmia-
dc.subject.otherFetal monitoring-
dc.subject.otherIschemia-
dc.titleFetal ischemia monitoring with in vivo implanted electrochemical multiparametric microsensors-
dc.typeinfo:eu-repo/semantics/article-
dc.typeinfo:eu-repo/semantics/publishedVersion-
dc.date.updated2022-01-03T10:36:48Z-
dc.relation.projectIDinfo:eu-repo/grantAgreement/EC/H2020/712754/EU//BEST-
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
dc.identifier.idimarina6542782-
dc.identifier.pmid34930385-
Appears in Collections:Articles publicats en revistes (Enginyeria Electrònica i Biomèdica)
Articles publicats en revistes (Institut de Bioenginyeria de Catalunya (IBEC))
Publicacions de projectes de recerca finançats per la UE
Articles publicats en revistes (BCNatal Fetal Medicine Research Center)

Files in This Item:
File Description SizeFormat 
12537_6542782_s13036-021-00280-7.pdf2.53 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons