Please use this identifier to cite or link to this item: http://hdl.handle.net/2445/184511
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSánchez Gonzalo, David-
dc.contributor.authorGómez Fernández, Sergio-
dc.contributor.authorFernandez-Tenllado, José María-
dc.contributor.authorBallabriga, Rafael-
dc.contributor.authorCampbell, Michael-
dc.contributor.authorGascón Fora, David-
dc.date.accessioned2022-03-29T17:22:35Z-
dc.date.available2022-03-29T17:22:35Z-
dc.date.issued2021-05-19-
dc.identifier.issn0168-9002-
dc.identifier.urihttp://hdl.handle.net/2445/184511-
dc.description.abstractThe Silicon Photomultiplier (SiPM) sensor is replacing the extensive use of the Photomultiplier Tube (PMT) in fast timing applications. These photo-sensors can be applied in different fields such as medical imaging systems like Positron Emission Tomography (PET), LIDAR technologies or High Energy Physics (HEP) experiments. More specific, Time-of-Flight PET (ToF-PET) requires further developments to achieve a Coincidence Time Resolution (CTR) of 10ps, this enabling the real time reconstruction and in vivo molecular examination. The most recent state-of-the-art ToF-PET systems can reach 200 ps in CTR. Lowering this value will require a cross-optimization of the scintillator crystal, the sensor and the electronics at the same time. These three elements optimization will be the key to boost the timing resolution of the complete system. The aim of this work is to provide a simulation framework that enables this cross-optimization of the PET system taking into consideration the photon physics interaction in the scintillator crystal, the sensor response (size, dead area, capacitance) and the readout electronics behavior (input impedance, noise, bandwidth). This framework has allowed us to study a new promising approach that helps reducing the CTR parameter by segmenting a large area SiPM into ?m?smaller SiPMs and then, summing the signals to recover all the signal spread along these smaller sensors. A 15% improvement on time resolution is expected by segmenting a 4 mm x 4 mm single sensor into 9 sensors of 1.3 mm x 1.3 mm with respect to the case where no segmentation is applied. The Silicon Photomultiplier (SiPM) sensor is replacing the extensive use of the Photomultiplier Tube (PMT) in fast timing applications. These photo-sensors can be applied in different fields such as medical imaging systems like Positron Emission Tomography (PET), LIDAR technologies or High Energy Physics (HEP) experiments. More specific, Time-of-Flight PET (ToF-PET) requires further developments to achieve a Coincidence Time Resolution (CTR) of 10ps, this enabling the real time reconstruction and in vivo molecular examination. The most recent state-of-the-art ToF-PET systems can reach 200 ps in CTR. Lowering this value will require a cross-optimization of the scintillator crystal, the sensor and the electronics at the same time. These three elements optimization will be the key to boost the timing resolution of the complete system. The aim of this work is to provide a simulation framework that enables this cross-optimization of the PET system taking into consideration the photon physics interaction in the scintillator crystal, the sensor response (size, dead area, capacitance) and the readout electronics behavior (input impedance, noise, bandwidth). This framework has allowed us to study a new promising approach that helps reducing the CTR parameter by segmenting a large area SiPM into ?m?smaller SiPMs and then, summing the signals to recover all the signal spread along these smaller sensors. A 15% improvement on time resolution is expected by segmenting a 4 mm x 4 mm single sensor into 9 sensors of 1.3 mm x 1.3 mm with respect to the case where no segmentation is applied.-
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherElsevier B.V.-
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.1016/j.nima.2021.165247-
dc.relation.ispartofNuclear Instruments & Methods in Physics Research Section A-Accelerators Spectrometers Detectors and Associated Equipment, 2021, vol. 1001, num. 13, p. 165247-
dc.relation.urihttps://doi.org/10.1016/j.nima.2021.165247-
dc.rightscc-by-nc-nd (c) Sánchez Gonzalo, David, et al., 2021-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.sourceArticles publicats en revistes (Física Quàntica i Astrofísica)-
dc.subject.classificationSilici-
dc.subject.classificationDetectors de radiació-
dc.subject.classificationElectrònica-
dc.subject.otherSilicon-
dc.subject.otherNuclear counters-
dc.subject.otherElectronics-
dc.titleMultimodal simulation of large area silicon photomultipliers for time resolution optimization-
dc.typeinfo:eu-repo/semantics/article-
dc.typeinfo:eu-repo/semantics/publishedVersion-
dc.identifier.idgrec717784-
dc.date.updated2022-03-29T17:22:35Z-
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
Appears in Collections:Articles publicats en revistes (Física Quàntica i Astrofísica)
Articles publicats en revistes (Institut de Ciències del Cosmos (ICCUB))

Files in This Item:
File Description SizeFormat 
717784.pdf2.29 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons