Please use this identifier to cite or link to this item: http://hdl.handle.net/2445/200789
Full metadata record
DC FieldValueLanguage
dc.contributor.authorRivas, Lourdes-
dc.contributor.authorDulay, Samuel-
dc.contributor.authorMiserere, Sandrine-
dc.contributor.authorPla, Laura-
dc.contributor.authorBerdún Marin, Sergio-
dc.contributor.authorParra, Johanna-
dc.contributor.authorEixarch Roca, Elisenda-
dc.contributor.authorGratacós Solsona, Eduard-
dc.contributor.authorIlla Armengol, Míriam-
dc.contributor.authorMir Llorente, Mònica-
dc.contributor.authorSamitier i Martí, Josep-
dc.date.accessioned2023-07-17T12:28:18Z-
dc.date.available2023-07-17T12:28:18Z-
dc.date.issued2020-04-01-
dc.identifier.issn0956-5663-
dc.identifier.urihttp://hdl.handle.net/2445/200789-
dc.description.abstractOxygen is vital for energy metabolism in mammals and the variability of the concentration is considered a clinical alert for a wide range of metabolic malfunctions in medicine. In this article, we describe the development and application of a micro-needle implantable platinum-based electrochemical sensor for measuring partial pressure of oxygen in intramuscular tissue (in-vivo) and vascular blood (ex-vivo). The Pt-Nafion® sensor was characterized morphological and electrochemically showing a higher sensitivity of -2.496 nA/mmHg (-1.495 nA/μM) when comparing with its bare counterpart. Our sensor was able to discriminate states with different oxygen partial pressures (pO2) for ex-vivo (blood) following the same trend of the commercial gas analyzer used as standard. For in-vivo (intramuscular) experiments, since there is not a gold standard for measuring pO2 in tissue, it was not possible to correlate the obtained currents with the pO2 in tissue. However, our sensor was able to detect clear statistical differences of O2 between hyperoxia and hypoxia states in tissue.-
dc.format.extent20 p.-
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherElsevier B.V.-
dc.relation.isformatofVersió postprint del document publicat a: https://doi.org/10.1016/j.bios.2020.112028-
dc.relation.ispartofBiosensors & Bioelectronics, 2020, vol. 153, num. 112028-
dc.relation.urihttps://doi.org/10.1016/j.bios.2020.112028-
dc.rightscc-by-nc-nd (c) Elsevier B.V., 2020-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.sourceArticles publicats en revistes (Cirurgia i Especialitats Medicoquirúrgiques)-
dc.subject.classificationBiosensors-
dc.subject.classificationElèctrodes-
dc.subject.classificationElectroquímica-
dc.subject.classificationOxigen-
dc.subject.classificationElectrònica mèdica-
dc.subject.otherBiosensors-
dc.subject.otherElectrodes-
dc.subject.otherElectrochemistry-
dc.subject.otherOxygen-
dc.subject.otherMedical electronics-
dc.titleMicro-needle implantable electrochemical oxygen sensor: ex-vivo and in-vivo studies-
dc.typeinfo:eu-repo/semantics/article-
dc.typeinfo:eu-repo/semantics/acceptedVersion-
dc.identifier.idgrec707908-
dc.date.updated2023-07-17T12:28:18Z-
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
dc.identifier.pmid31989937-
Appears in Collections:Articles publicats en revistes (BCNatal Fetal Medicine Research Center)
Articles publicats en revistes (Institut de Bioenginyeria de Catalunya (IBEC))
Articles publicats en revistes (Cirurgia i Especialitats Medicoquirúrgiques)
Articles publicats en revistes (Enginyeria Electrònica i Biomèdica)
Articles publicats en revistes (IDIBAPS: Institut d'investigacions Biomèdiques August Pi i Sunyer)

Files in This Item:
File Description SizeFormat 
707908.pdf1.63 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons