dc.description.abstract | Inductive-based devices integrated with Si technology for biodetection applications are characterized, using simple resonant differential filter configurations. This has allowed the corroboration of the viability of the proposed circuits, which are characterized by their very high simplicity, for microinductive signal conditioning in high-sensitivity sensor devices. The simulation of these simple circuits predicts sensitivities of the differential output voltage which can achieve values in the range of 0.1-1 V/nH, depending on the coil parameters. These very high-sensitivity values open the possibility for the experimental detection of extremely small inductance changes in the devices. For real microinductive devices, both series resistance and parasitic capacitive components contribute to the decrease of the differential circuit sensitivity. Nevertheless, measurements performed using micro-coils fabricated with relatively high series resistance and coupling parasitic effects have allowed detection of changes in the range of 2 nH. which are compatible with biodetection applications with estimated detection limits below the picomolarity range. | eng |
dc.format.extent | 6 p. | cat |
dc.format.mimetype | application/pdf | eng |
dc.language.iso | eng | eng |
dc.publisher | IEEE | cat |
dc.relation.isformatof | Reproducció del document publicat a http://dx.doi.org/10.1109/TIM.2007.895593 | cat |
dc.relation.ispartof | IEEE Transactions on Instrumentation and Measurement, 2007, vol. 56, núm. 5, p. 1590-1595. | cat |
dc.relation.uri | http://dx.doi.org/10.1109/TIM.2007.895593 | - |
dc.rights | (c) IEEE, 2007 | cat |
dc.source | Articles publicats en revistes (Enginyeria Electrònica i Biomèdica) | - |
dc.subject.classification | Detectors de partícules | cat |
dc.subject.other | Biosensors | eng |
dc.subject.other | Magnetic particles | eng |
dc.subject.other | Microsensors | eng |
dc.subject.other | Passive filters | eng |
dc.subject.other | Signal processing equipment | eng |
dc.subject.other | Silicon | eng |
dc.title | Microinductive signal conditioning with resonant differential filters: high-sensitivity biodetection applications | eng |
dc.type | info:eu-repo/semantics/article | eng |
dc.type | info:eu-repo/semantics/publishedVersion | - |
dc.identifier.idgrec | 553862 | cat |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | - |
Appears in Collections: | Articles publicats en revistes (Enginyeria Electrònica i Biomèdica) |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
553862.pdf | 287.98 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.