Please use this identifier to cite or link to this item: http://hdl.handle.net/2445/8758
Full metadata record
DC FieldValueLanguage
dc.contributor.authorBaglio, Salvatore-
dc.contributor.authorPérez Rodríguez, Alejandro-
dc.contributor.authorMartínez Mendizábal, Susana-
dc.contributor.authorSerre, Christophe-
dc.contributor.authorMorante i Lleonart, Joan Ramon-
dc.contributor.authorEsteve Tintó, Jaume-
dc.contributor.authorMontserrat i Martí, Josep-
dc.date.accessioned2009-06-19T08:13:53Z-
dc.date.available2009-06-19T08:13:53Z-
dc.date.issued2007cat
dc.identifier.issn0018-9456-
dc.identifier.urihttp://hdl.handle.net/2445/8758-
dc.description.abstractInductive-based devices integrated with Si technology for biodetection applications are characterized, using simple resonant differential filter configurations. This has allowed the corroboration of the viability of the proposed circuits, which are characterized by their very high simplicity, for microinductive signal conditioning in high-sensitivity sensor devices. The simulation of these simple circuits predicts sensitivities of the differential output voltage which can achieve values in the range of 0.1-1 V/nH, depending on the coil parameters. These very high-sensitivity values open the possibility for the experimental detection of extremely small inductance changes in the devices. For real microinductive devices, both series resistance and parasitic capacitive components contribute to the decrease of the differential circuit sensitivity. Nevertheless, measurements performed using micro-coils fabricated with relatively high series resistance and coupling parasitic effects have allowed detection of changes in the range of 2 nH. which are compatible with biodetection applications with estimated detection limits below the picomolarity range.eng
dc.format.extent6 p.cat
dc.format.mimetypeapplication/pdfeng
dc.language.isoengeng
dc.publisherIEEEcat
dc.relation.isformatofReproducció del document publicat a http://dx.doi.org/10.1109/TIM.2007.895593cat
dc.relation.ispartofIEEE Transactions on Instrumentation and Measurement, 2007, vol. 56, núm. 5, p. 1590-1595.cat
dc.relation.urihttp://dx.doi.org/10.1109/TIM.2007.895593-
dc.rights(c) IEEE, 2007cat
dc.sourceArticles publicats en revistes (Enginyeria Electrònica i Biomèdica)-
dc.subject.classificationDetectors de partículescat
dc.subject.otherBiosensorseng
dc.subject.otherMagnetic particleseng
dc.subject.otherMicrosensorseng
dc.subject.otherPassive filterseng
dc.subject.otherSignal processing equipmenteng
dc.subject.otherSiliconeng
dc.titleMicroinductive signal conditioning with resonant differential filters: high-sensitivity biodetection applicationseng
dc.typeinfo:eu-repo/semantics/articleeng
dc.typeinfo:eu-repo/semantics/publishedVersion-
dc.identifier.idgrec553862cat
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
Appears in Collections:Articles publicats en revistes (Enginyeria Electrònica i Biomèdica)

Files in This Item:
File Description SizeFormat 
553862.pdf287.98 kBAdobe PDFView/Open