Please use this identifier to cite or link to this item:
https://hdl.handle.net/2445/125334
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Martínez Monge, Álvaro | - |
dc.contributor.author | Mañosas Castejón, María | - |
dc.contributor.author | Ritort Farran, Fèlix | - |
dc.date.accessioned | 2018-10-16T11:44:04Z | - |
dc.date.available | 2018-10-16T11:44:04Z | - |
dc.date.issued | 2018-09-28 | - |
dc.identifier.issn | 1539-3755 | - |
dc.identifier.uri | https://hdl.handle.net/2445/125334 | - |
dc.description.abstract | We experimentally test the validity of the Crooks fluctuation theorem (CFT) in the force ensemble by pulling DNA hairpins, first with magnetic tweezers, next with optical tweezers using force feedback. The CFT holds when using the definition of work Wf=−∫xdf, where x is the molecular extension and f is the force. In contrast, it does not hold when using the usual definition, appropriate for the constant extension ensemble, Wx=∫fdx, showing the importance of the contribution of boundary terms to the full entropy production in a clear example of statistical ensemble inequivalence in small systems. We also evaluate the differences in the average dissipated work in the force ensemble as compared to the extension ensemble, highlighting ensemble inequivalence also at the level of molecular kinetics. | - |
dc.format.extent | 9 p. | - |
dc.format.mimetype | application/pdf | - |
dc.language.iso | eng | - |
dc.publisher | American Physical Society | - |
dc.relation.isformatof | Reproducció del document publicat a: https://doi.org/10.1103/PhysRevE.98.032146 | - |
dc.relation.ispartof | Physical Review E, 2018, vol. 98, num. 3 | - |
dc.relation.uri | https://doi.org/10.1103/PhysRevE.98.032146 | - |
dc.rights | (c) American Physical Society, 2018 | - |
dc.source | Articles publicats en revistes (Física de la Matèria Condensada) | - |
dc.subject.classification | Aparells i instruments científics | - |
dc.subject.classification | Dispositius optoelectrònics | - |
dc.subject.classification | Mecànica estadística | - |
dc.subject.other | Scientific apparatus and instruments | - |
dc.subject.other | Optoelectronic devices | - |
dc.subject.other | Statistical mechanics | - |
dc.title | Experimental test of ensemble inequivalence and the fluctuation theorem in the force ensemble in DNA pulling experiments | - |
dc.type | info:eu-repo/semantics/article | - |
dc.type | info:eu-repo/semantics/publishedVersion | - |
dc.identifier.idgrec | 682359 | - |
dc.date.updated | 2018-10-16T11:44:04Z | - |
dc.relation.projectID | info:eu-repo/grantAgreement/EC/H2020/687089/EU//PROSEQO | - |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | - |
Appears in Collections: | Articles publicats en revistes (Física de la Matèria Condensada) |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
682359.pdf | 1.44 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.