Title: Novel ball head screw and screwdriver design for implant-supported prostheses with angled channels: a finite element analysis
Author: Farré Berga, Oriol
Cercadillo-Ibarguren, Iñaki
Sánchez Torres, Alba
Domènech-Mestres, Carles
Gil, F. X. (Francesc Xavier)
Escuin Henar, Tomás J. (Tomás José)
Berástegui, Esther
Keywords: Pròtesis dentals
Implants dentals
Aparells i instruments odontològics
Mètode dels elements finits
Dental prosthesis
Dental implants
Dental instruments and apparatus
Finite element method
Issue Date: 1-Dec-2018
Publisher: American Association of Implant Dentistry
Abstract: The primary objective of this study was to design the optimal geometry of a novel screwdriver, create the grooves on a ball head screw, and demonstrate its resistance to a torque of up to 40 Ncm at angulations of 0°, 15°, and 30° by using nonlinear finite element analysis. A secondary objective was to create a foolproof, easily recognizable system. The grooved ball head screw and geometry of the screwdriver, functioning from an angulation of 0° to 30°, was generated using Pro-ENGINEER Wildfire 5.0 software. Static structural analyses among bodies in contact were performed at different angles of 0°, 15°, and 30° at a torque of 20 Ncm and 40 Ncm using nonlinear finite element simulation by means of ANSYS 12.0. The maximum stress supported by the ball head screw and screwdriver was similar at 20 Ncm and 40 Ncm. Although greater deformations were found at 40 Ncm, these were small and might not affect the performance of the system. Further, the rupture torque value for the M2 connection was 55 Ncm for 0° and 30°, and 47.5 Ncm for 15°. Numerical simulation showed that the ball head system design can achieve the mechanical strength requirements expected for screws used in implant-supported restorations at an angulation of up to 30°. Finite element analysis showed this novel ball head screw and screwdriver system to be a good solution for angled screw channels in implant-supported prostheses.
Note: Versió postprint del document publicat a: https://doi.org/10.1563/aaid-joi-D-18-00103
It is part of: Journal of Oral Implantology, 2018, vol. 44, num. 6, p. 416-422
URI: http://hdl.handle.net/2445/127702
Related resource: https://doi.org/10.1563/aaid-joi-D-18-00103
ISSN: 0160-6972
Appears in Collections:Articles publicats en revistes (Odontoestomatologia)
Articles publicats en revistes (Institut d'lnvestigació Biomèdica de Bellvitge (IDIBELL))

Files in This Item:
File Description SizeFormat 
683415.pdf1.33 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.