Please use this identifier to cite or link to this item: http://hdl.handle.net/2445/184614
Full metadata record
DC FieldValueLanguage
dc.contributor.authorRodriguez Temporal, David-
dc.contributor.authorRodríguez-Sánchez, Belén-
dc.contributor.authorAlcaide Fernández de Vega, Fernando-
dc.date.accessioned2022-04-01T13:03:23Z-
dc.date.available2022-04-01T13:03:23Z-
dc.date.issued2020-09-22-
dc.identifier.issn0095-1137-
dc.identifier.urihttp://hdl.handle.net/2445/184614-
dc.description.abstractIdentification of mycobacteria by matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) requires not only a good protein extraction protocol but also an adequate cutoff score in order to provide reliable results. The aim of this study was to assess the cutoff scores proposed by the MALDI-TOF MS system for mycobacterial identification. A total of 693 clinical isolates from a liquid medium and 760 from a solid medium were analyzed, encompassing 67 different species of nontuberculous mycobacteria (NTM). MALDI-TOF MS identified 558 (80.5%) isolates from the liquid medium and 712 (93.7%) isolates from the solid medium with scores of ≥1.60. Among these, four (0.7%) misidentifications were obtained from the liquid medium and four (0.5%) from the solid medium. With regard to species diversity, MALDI-TOF MS successfully identified 64 (95.5%) different species, while PCR-reverse hybridization (GenoType Mycobacterium CM and AS assays) identified 24 (35.8%) different species. With MALDI-TOF MS scores of ≥2, all isolates were correctly identified, and with scores in the range from 1.60 to 1.99, most isolates were correctly identified, except for Mycobacterium angelicum, M. parascrofulaceum, M. peregrinum, M. porcinum, and M. gastri. In conclusion, MALDI-TOF MS is a useful method for identifying a large diversity of NTM species. A score threshold of 1.60 proved useful for identifying almost all the isolates tested; only a few species required a higher score (≥2.00) to obtain a valid definitive identification.-
dc.format.extent21 p.-
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherAmerican Society for Microbiology-
dc.relation.isformatofVersió postprint del document publicat a: https://doi.org/10.1128/JCM.01103-20-
dc.relation.ispartofJournal of Clinical Microbiology, 2020, vol. 58, num. 10, p. e01103-20-
dc.relation.urihttps://doi.org/10.1128/JCM.01103-20-
dc.rights(c) American Society for Microbiology, 2020-
dc.sourceArticles publicats en revistes (Patologia i Terapèutica Experimental)-
dc.subject.classificationMicobacteris-
dc.subject.classificationDesorció-ionització amb làser assistit per matriu-
dc.subject.classificationGenètica-
dc.subject.otherMycobacteria-
dc.subject.otherMatrix-assisted laser desorption-ionization-
dc.subject.otherGenetics-
dc.titleEvaluation of MALDI biotyper interpretation criteria for accurate identification of nontuberculous mycobacteria-
dc.typeinfo:eu-repo/semantics/article-
dc.typeinfo:eu-repo/semantics/acceptedVersion-
dc.identifier.idgrec708098-
dc.date.updated2022-04-01T13:03:24Z-
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
dc.identifier.pmid32719033-
Appears in Collections:Articles publicats en revistes (Patologia i Terapèutica Experimental)
Articles publicats en revistes (Institut d'lnvestigació Biomèdica de Bellvitge (IDIBELL))

Files in This Item:
File Description SizeFormat 
708098.pdf480.02 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.