Please use this identifier to cite or link to this item: http://hdl.handle.net/2445/197645
Full metadata record
DC FieldValueLanguage
dc.contributor.authorRiedelová, Zuzana-
dc.contributor.authorSantos Pereira, Andres de los-
dc.contributor.authorSvoboda, Jan-
dc.contributor.authorPop Georgievski, Ognen-
dc.contributor.authorMájek, Pavel-
dc.contributor.authorPečánková, Klára-
dc.contributor.authorDyčka, Filip-
dc.contributor.authorRodriguez Emmenegger, César-
dc.contributor.authorRiedel, Tomáš-
dc.date.accessioned2023-05-08T09:41:41Z-
dc.date.available2023-08-22T05:10:32Z-
dc.date.issued2022-08-02-
dc.identifier.issn1616-5195-
dc.identifier.urihttp://hdl.handle.net/2445/197645-
dc.description.abstractWhenever an artificial surface comes into contact with blood, proteins are rapidly adsorbed onto its surface. This phenomenon, termed fouling, is then followed by a series of undesired reactions involving activation of complement or the coagulation cascade and adhesion of leukocytes and platelets leading to thrombus formation. Thus, considerable efforts are directed towards the preparation of fouling-resistant surfaces with the best possible hemocompatibility. Herein, a comprehensive hemocompatibility study after heparinized blood contact with seven polymer brushes prepared by surface-initiated atom transfer radical polymerization is reported. The resistance to fouling is quantified and thrombus formation and deposition of blood cellular components on the coatings are analyzed. Moreover, identification of the remaining adsorbed proteins is performed via mass spectroscopy to elucidate their influence on the surface hemocompatibility. Compared with an unmodified glass surface, the grafting of polymer brushes minimizes the adhesion of platelets and leukocytes and prevents the thrombus formation. The fouling from undiluted blood plasma is reduced by up to 99%. Most of the identified proteins are connected with the initial events of foreign body reaction towards biomaterial (coagulation cascade proteins, complement component, and inflammatory proteins). In addition, several proteins that are not previously linked with blood-biomaterial interaction are presented and discussed.ca
dc.format.extent25 p.-
dc.format.mimetypeapplication/pdf-
dc.language.isoengca
dc.publisherWileyca
dc.relation.isformatofVersió postprint del document publicat a: https://doi.org/10.1002/mabi.202200247-
dc.relation.ispartofMacromolecular Bioscience, 2022, vol. 22, num. 11, p. 2200247-
dc.relation.urihttps://doi.org/10.1002/mabi.202200247-
dc.rights(c) John Wiley & Sons, Inc, 2022-
dc.sourceArticles publicats en revistes (Institut de Bioenginyeria de Catalunya (IBEC))-
dc.subject.classificationTrombosi-
dc.subject.classificationMaterials biomèdics-
dc.subject.classificationPolímers en medicina-
dc.subject.otherThrombosis-
dc.subject.otherBiomedical materials-
dc.subject.otherPolymers in medicine-
dc.titleThe Relation Between Protein Adsorption and Hemocompatibility of Antifouling Polymer Brushesca
dc.typeinfo:eu-repo/semantics/articleca
dc.typeinfo:eu-repo/semantics/acceptedVersion-
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
dc.identifier.pmid35917216-
Appears in Collections:Articles publicats en revistes (Institut de Bioenginyeria de Catalunya (IBEC))

Files in This Item:
File Description SizeFormat 
2022_MacBio_Relation_Riedel_etal_postprint.pdf1.12 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.