Please use this identifier to cite or link to this item: http://hdl.handle.net/2445/212445
Title: A multicentre evaluation of the NG-test DetecTool OXA-23 for the rapid detection of OXA-23 carbapenemase directly from blood cultures
Author: Szabo, Dóra
Vasilakopoulou, Alexandra
Naas, Thierry
Gonzalez, Camille
Vila Grajales, Joaquim
Riccobono, Eleonora
Kamotsay, Katalin
Reissier, Sophie
Berbel, Dàmaris
Aszalos, Albert Zoltan
Rosenmoller, Magda
Stankov-Puges, Milovan
Georgiou, Panagiota Christina
Vourli, Sophia
Volland, Hervé
Pournaras, Spyros
Keywords: Immunoassaig
Bacteris
Antibiòtics
Immunoassay
Bacteria
Antibiotics
Issue Date: 7-Mar-2024
Publisher: Oxford University Press
Abstract: Objectives: A multicentre study evaluating NG-Test DetecTool OXA-23 for the detection of OXA-23 carbapenemase directly from positive blood cultures (PBCs). Methods: The NG-Test DetecTool OXA-23 is an immunoassay that integrates a sample preparation device. We evaluated NG-Test DetecTool OXA-23 on 189 spiked and 126 clinical PBCs. The clinical samples' standard-of-care procedure consisted of bacterial identification from the first day of positivity by MALDI-TOF MS, conventional culture and antimicrobial susceptibility testing. The immunoassay results were verified molecularly. The strains used for the spiked samples consisted of well-characterized Acinetobacter baumannii and Proteus mirabilis strains. Results: The NG-Test DetecTool OXA-23 was evaluated on 315 PBCs and revealed sensitivity of 100% (95% CI: 98.21%-100.00%) and specificity of 100% (95% CI: 96.73%-100.00%). It provided 204 true-positive results for OXA-23 in 196 bottles with carbapenem-resistant A. baumannii (CRAB) and 8 bottles with carbapenem-resistant P. mirabilis and also provided 111 true-negative results. There were no false-positive and no false-negative results. Among the 315 PBCs studied, 83 clinical blood cultures collected in the ICU of a Greek university hospital, which were tested prospectively, all yielded CRAB, and OXA-23 was correctly detected in all samples from the first day of positivity using the NG-Test DetecTool OXA-23. Conclusions: The NG-Test DetecTool OXA-23 has exhibited excellent sensitivity and specificity for OXA-23 detection in PBCs and can provide valuable information for appropriate selection of antibiotic therapy and early implementation of infection control measures.
Note: Reproducció del document publicat a: https://doi.org/10.1093/jacamr/dlae029
It is part of: Journal of Antimicrobial Chemotherapy, 2024, vol. 6, num.2
URI: http://hdl.handle.net/2445/212445
Related resource: https://doi.org/10.1093/jacamr/dlae029
ISSN: 0305-7453
Appears in Collections:Articles publicats en revistes (Institut d'lnvestigació Biomèdica de Bellvitge (IDIBELL))
Articles publicats en revistes (Fonaments Clínics)

Files in This Item:
File Description SizeFormat 
860353.pdf231.99 kBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons