Please use this identifier to cite or link to this item: https://hdl.handle.net/2445/217312
Full metadata record
DC FieldValueLanguage
dc.contributor.authorCases, Carla-
dc.contributor.authorOses, Gabriela-
dc.contributor.authorHerreros, Antonio-
dc.contributor.authorTarrats Rosell, Jordi-
dc.contributor.authorMoreno, Sara-
dc.contributor.authorMollà, Meritxell-
dc.date.accessioned2025-01-08T12:11:32Z-
dc.date.available2025-01-23T06:10:10Z-
dc.date.issued2024-07-01-
dc.identifier.issn1699-048X-
dc.identifier.urihttps://hdl.handle.net/2445/217312-
dc.description.abstractIntroduction: Intraoperative electron radiotherapy (IOERT) is a technique aiming to deliver radiotherapy during oncological surgery. In breast IOERT, the applicator and shielding disc placement are correlated with organs at risk (OAR) irradiation, in vivo verification of these parameters is scarcely reported. The aim of our study is to report and analyze possible causes of the misalignment using radiochromic films and compare our results to others reported in the bibliography. Methods: From November 2019 to April 2023, in vivo verifications were performed for 33 patients. IOERT was performed using a LIAC 10 MeV (Sordina, Italy) electron accelerator. We attached a radiochromic film to the upper side of the polytetrafluoroethylene cover of the shielding disc. The percentage of the irradiation area outside the disc was recorded and various parameters (applicator angulations, prescription depth, tumor location and breast size) were analyzed to find possible correlations. Results: For 29 patients, 20 Gy were prescribed while 10 Gy were prescribed to 4 patients. The average irradiated area outside the disc was 19% (0-56%) corresponding to a surface of 4.5 cm2 (0-17.4 cm2). The applicator of 5 cm was used for most of the patients. The mean prescription depth was 1.4 cm (0.5-2.5 cm). We found no correlation between the analyzed parameters and misalignment. Conclusion: This study confirms the presence and magnitude of the misalignments. We strongly recommend in vivo verifications as a quality check during IOERT procedures. The misalignment has no correlation with tumor localization parameters, so the solution could be based on technical improvements of the applicator.-
dc.format.extent16 p.-
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherSpringer Verlag-
dc.relation.isformatofVersió postprint del document publicat a: https://doi.org/10.1007/s12094-023-03378-0-
dc.relation.ispartofClinical & Translational Oncology, 2024, vol. 26, num.7, p. 1623-1629-
dc.relation.urihttps://doi.org/10.1007/s12094-023-03378-0-
dc.rights(c) Federación de Sociedades Españolas de Oncología (FESEO), 2024-
dc.sourceArticles publicats en revistes (Fonaments Clínics)-
dc.subject.classificationCirurgia de la mama-
dc.subject.classificationRadioteràpia-
dc.subject.classificationCàncer de mama-
dc.subject.classificationElectrons-
dc.subject.classificationEfectes fisiològics de les radiacions-
dc.subject.otherBreast surgery-
dc.subject.otherRadiotherapy-
dc.subject.otherBreast cancer-
dc.subject.otherElectrones-
dc.subject.otherPhysiological effects of radiation-
dc.subject.otherQuality control-
dc.subject.otherControl de qualitat-
dc.titleOn the need of in vivo verifications as quality control for intraoperative electron radiotherapy in breast cancer-
dc.typeinfo:eu-repo/semantics/article-
dc.typeinfo:eu-repo/semantics/acceptedVersion-
dc.date.updated2025-01-08T12:11:32Z-
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
dc.identifier.idimarina9384067-
dc.identifier.pmid38267659-
Appears in Collections:Articles publicats en revistes (Fonaments Clínics)
Articles publicats en revistes (IDIBAPS: Institut d'investigacions Biomèdiques August Pi i Sunyer)

Files in This Item:
File Description SizeFormat 
874693.pdf472.01 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.