Please use this identifier to cite or link to this item: http://hdl.handle.net/2445/142658
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSolórzano, Ana-
dc.contributor.authorRodríguez-Pérez, Raquel-
dc.contributor.authorPadilla, Marta-
dc.contributor.authorGraunke, Thorsten-
dc.contributor.authorFernández Romero, Luis-
dc.contributor.authorMarco Colás, Santiago-
dc.contributor.authorFonollosa, Jordi-
dc.date.accessioned2019-10-21T13:52:14Z-
dc.date.available2020-07-15T05:10:25Z-
dc.date.issued2018-07-15-
dc.identifier.issn0925-4005-
dc.identifier.urihttp://hdl.handle.net/2445/142658-
dc.description.abstractInherent sensor variability limits mass-production applications for metal oxide (MOX) gas sensor arrays because calibration for replicas of a sensor array needs to be performed individually. Recently, calibration transfer strategies have been proposed to alleviate calibration costs of new replicas, but they still require the acquisition of transfer samples. In this work, we present calibration models that can be extended to uncalibrated replicas of sensor arrays without acquiring new samples, i.e., general or global calibration models. The developed methodology consists in including multiple replicas of a sensor array in the calibration process such that sensor variability is rejected by the general model. Our approach was tested using replicas of a MOX sensor array in the classification task of six gases and synthetic air, presented at different background humidity and concentration levels. Results showed that direct transfer of individual calibration models provides poor classification accuracy. However, we also found that general calibration models kept predictive performance when were applied directly to new copies of the sensor array. Moreover, we explored, through feature selection, whether particular combinations of sensors and operating temperatures can provide predictive performances equivalent to the calibration model with the complete array, favoring thereby the existence of more robust calibration models.-
dc.format.extent30 p.-
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherElsevier B.V.-
dc.relation.isformatofVersió postprint del document publicat a: https://doi.org/10.1016/j.snb.2018.02.188-
dc.relation.ispartofSensors and Actuators B-Chemical, 2018, vol. 265, p. 142-154-
dc.relation.urihttps://doi.org/10.1016/j.snb.2018.02.188-
dc.rightscc-by-nc-nd (c) Elsevier B.V., 2018-
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es-
dc.sourceArticles publicats en revistes (Enginyeria Electrònica i Biomèdica)-
dc.subject.classificationDinàmica de gasos-
dc.subject.classificationCalibratge-
dc.subject.otherGas dynamics-
dc.subject.otherCalibration-
dc.titleMulti-unit calibration rejects inherent device variability of chemical sensor arrays-
dc.typeinfo:eu-repo/semantics/article-
dc.typeinfo:eu-repo/semantics/acceptedVersion-
dc.identifier.idgrec691696-
dc.date.updated2019-10-21T13:52:14Z-
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
Appears in Collections:Articles publicats en revistes (Enginyeria Electrònica i Biomèdica)
Articles publicats en revistes (Institut de Bioenginyeria de Catalunya (IBEC))

Files in This Item:
File Description SizeFormat 
691696.pdf291.16 kBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons