Please use this identifier to cite or link to this item: http://hdl.handle.net/2445/184803
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMancera Arteu, Montserrat-
dc.contributor.authorLleshi, Nejsi-
dc.contributor.authorSanz Nebot, María Victoria-
dc.contributor.authorGiménez López, Estela-
dc.contributor.authorBenavente Moreno, Fernando J. (Julián)-
dc.date.accessioned2022-04-08T11:16:11Z-
dc.date.available2022-04-08T11:16:11Z-
dc.date.issued2020-01-15-
dc.identifier.issn0039-9140-
dc.identifier.urihttp://hdl.handle.net/2445/184803-
dc.description.abstractIn this study is described an on-line titanium dioxide solid-phase extraction capillary electrophoresis-mass spectrometry (TiO2-SPE-CE-MS) method for the analysis of the glycopeptide glycoforms obtained from the tryptic digests of recombinant human erythropoietin (rhEPO). The O126-glycopeptide of rhEPO was used to optimize the methodology given its importance in quality control of biopharmaceuticals and doping analysis. Several aspects that affect the selective retention and elution, peak efficiency and electrophoretic separation of the O126 glycoforms were investigated to maximize detection sensitivity while minimizing non-specific retention of peptides. Under the optimized conditions, the microcartridge lifetime was around 10 analyses and repeatability was acceptable (%RSD values of 9-11% and 6-11% for migration times and peak areas, respectively). The method was linear between 0.5-50 mg·L-1 and 10-50 mg·L-1 for O126 glycoforms containing NeuAc and NeuGc, respectively, and limits of detection (LODs) were up to 100 times lower than by CE-MS. Although optimized for O-glycopeptides, the method proved also successful for preconcentration of N83-glycopeptides, without compromising the separation between glycopeptide glycoforms with different number of sialic acids. Tryptic digests of other glycoproteins (i.e. human apolipoprotein CIII (APO-C3) and bovine alpha-1-acid glycoprotein (bAGP)) were also analyzed, demonstrating the applicability to glycopeptides with different glycan composition and nature.-
dc.format.extent38 p.-
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherElsevier B.V.-
dc.relation.isformatofVersió postprint del document publicat a: https://doi.org/10.1016/j.talanta.2019.120563-
dc.relation.ispartofTalanta, 2020, vol. 209, num. 120563-
dc.relation.urihttps://doi.org/10.1016/j.talanta.2019.120563-
dc.rightscc-by-nc-nd (c) Elsevier B.V., 2020-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.sourceArticles publicats en revistes (Enginyeria Química i Química Analítica)-
dc.subject.classificationDiòxid de titani-
dc.subject.classificationEspectrometria de masses-
dc.subject.classificationMarcadors bioquímics-
dc.subject.classificationElectroforesi capil·lar-
dc.subject.classificationGlicoproteïnes-
dc.subject.otherTitanium dioxide-
dc.subject.otherMass spectrometry-
dc.subject.otherBiochemical markers-
dc.subject.otherCapillary electrophoresis-
dc.subject.otherGlycoproteins-
dc.titleAnalysis of glycopeptide biomarkers by on-line TiO2 solid-phase extraction capillary electrophoresis-mass spectrometry-
dc.typeinfo:eu-repo/semantics/article-
dc.typeinfo:eu-repo/semantics/acceptedVersion-
dc.identifier.idgrec691980-
dc.date.updated2022-04-08T11:16:11Z-
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess-
dc.identifier.pmid31892091-
Appears in Collections:Articles publicats en revistes (Enginyeria Química i Química Analítica)
Articles publicats en revistes (Institut de Recerca en Nutrició i Seguretat Alimentària (INSA·UB))

Files in This Item:
File Description SizeFormat 
691980.pdf802.86 kBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons