Towards batch correction for GC-IMS data

dc.contributor.authorFernández Romero, Luis
dc.contributor.authorBlanco i Borrego, Arnau
dc.contributor.authorMallafré Muro, Celia
dc.contributor.authorMarco Colás, Santiago
dc.date.accessioned2025-03-25T09:48:15Z
dc.date.available2025-03-25T09:48:15Z
dc.date.issued2022-06-10
dc.date.updated2025-03-17T15:02:29Z
dc.description.abstractGas Chromatography Ion Mobility Spectrometry (GC-IMS) is a fast, non-expensive analytical technique that allows obtaining relevant chemical information from vapor mixtures. However, the technique presents some difficulties that should be solved to ensure reliable and reproducible results, namely: 1) data exhibits simultaneously high dimensionality and sparsity on their chemical information content, 2) data samples must usually be corrected even within a batch because of baseline and misalignment problems, 3) additional data corrections must be performed to prevent from chemical fingerprinting variations among batches. In this work, we have acquired data from two different batches (A and B) of ketone mixtures (2-Butanone, 2-Pentanone, 2-Hexanone, and 2-Heptanone). The analytical method for batch A and B was the same, except for the value of carrier gas flow parameter, which was approximately doubled for batch B. We have addressed problems 1) and 2) independently for each batch, obtaining as a result two peak tables. 3). Common peaks present in batches A and B were found after scaling the retention time axis of batch B and perform k-medoids clustering. Using this information, test data from batch B has been corrected through a linear transformation.
dc.format.extent3 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec476607
dc.identifier.idimarina6572618
dc.identifier.idsira732926
dc.identifier.urihttps://hdl.handle.net/2445/219968
dc.language.isoeng
dc.publisherIEEE
dc.relation.isformatofVersió postprint del document publicat a: https://doi.org/10.1109/ISOEN54820.2022.9789646
dc.relation.ispartofComunicació a: 2022 IEEE International Symposium on Olfaction and Electronic Nose (ISOEN), International Society for Olfaction and Chemical Sensing (ISOCS), Aveiro, Portugal, 29 de maig - 1 de juny 2022
dc.relation.urihttps://doi.org/10.1109/ISOEN54820.2022.9789646
dc.rights(c) IEEE, 2022
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.sourceComunicacions a congressos (Enginyeria Electrònica i Biomèdica)
dc.subject.classificationCromatografia de gasos
dc.subject.classificationDactiloscòpia
dc.subject.otherGas chromatography
dc.subject.otherFingerprints
dc.titleTowards batch correction for GC-IMS data
dc.typeinfo:eu-repo/semantics/conferenceObject
dc.typeinfo:eu-repo/semantics/acceptedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
2022_ISOEN_Towards_MarcoS_Postprint.pdf
Mida:
203.55 KB
Format:
Adobe Portable Document Format