Effect of temperature and flow rate on the cell-free area in the microfluidic channel

dc.contributor.authorRodríguez-Villarreal, Ivón
dc.contributor.authorCarmona Flores, Manuel
dc.contributor.authorColomer i Farrarons, Jordi
dc.date.accessioned2021-04-16T09:50:15Z
dc.date.available2021-04-16T09:50:15Z
dc.date.issued2021-02-03
dc.date.updated2021-04-16T09:50:15Z
dc.description.abstractBlood cell manipulation in microdevices is an interesting task for the separation of particles, by their size, density, or to remove them from the buffer, in which they are suspended, for further analysis, and more. This study highlights the cell-free area (CFA) widening based on experimental results of red blood cell (RBC) flow, suspended in a microfluidic device, while temperature and flow rate incrementally modify RBC response within the microflow. Studies of human red blood cell flow, at a concentration of 20%, suspended in its autologous plasma and phosphate-buffered saline (PBS) buffer, were carried out at a wide flow rate, varying between 10 and 230 µL/min and a temperature range of 23 ◦C to 50 ◦C. The plotted measures show an increment in a CFA near the channel wall due to cell flow inertia after a constricted channel, which becomes more significant as temperature and flow rate increase. The temperature increment widened the CFA up to three times. In comparison, flow rate increment increased the CFA up to 20 times in PBS and 11 times in plasma.
dc.format.extent14 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec711171
dc.identifier.issn2077-0375
dc.identifier.pmid33546403
dc.identifier.urihttps://hdl.handle.net/2445/176380
dc.language.isoeng
dc.publisherMDPI
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.3390/membranes11020109
dc.relation.ispartofMembranes, 2021, vol. 11, num. 2, p. 109-122
dc.relation.urihttps://doi.org/10.3390/membranes11020109
dc.rightscc-by (c) Rodríguez-Villarreal, Ivón et al., 2021
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es
dc.sourceArticles publicats en revistes (Enginyeria Electrònica i Biomèdica)
dc.subject.classificationMicrofluídica
dc.subject.classificationPlasma sanguini
dc.subject.classificationCirculació sanguínia
dc.subject.otherMicrofluidics
dc.subject.otherBlood plasma
dc.subject.otherCirculation of the blood
dc.titleEffect of temperature and flow rate on the cell-free area in the microfluidic channel
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers