Files
Document type
ArticleVersion
Accepted versionPublication date
Publication license
Please use this identifier to cite or link to this item: https://hdl.handle.net/2445/197401
Assessment of dead-end ultrafiltration for the detection and quantification of microbial indicators and pathogens in the drinking water treatment processes
Journal Title
Director/Tutor
Journal ISSN
Volume Title
Related resource
Abstract
A safe water supply requires distinct treatments and monitoring to guarantee the absence of pathogens and substances potentially hazardous for human health. In this study we assessed the efficiency of the dead-end ultrafiltration (DEUF) method to concentrate faecal indicator organisms (FIO) and pathogens in water samples with different physicochemical characteristics. Water samples were collected at the treatment stages of two drinking water treatment plants to analyse the concentration of a variety of 7 FIO and 4 reference microbes which have some species that are pathogenic to humans: Campylobacter spp., enteroviruses, Cryptosporidium spp. and Giardia spp. The samples were analysed before and after concentration by DEUF, detecting FIO concentrations about 1 log10 higher in non-concentrated samples from both catchments. Percent recoveries were highly variable with a mean of 43.8 ± 17.5%, depending on the FIO and inherent sample characteristics. However, DEUF enabled FIO concentration in high volumes of water (100-500 l), allowing a reduction in the detection limit compared to the non-concentrated samples due to the high volume processing capabilities of the method. As a consequence, the detection of FIO removal from water in the drinking water treatment process was 1.0-1.5 logarithms greater in DEUF-treated water compared to unfiltered samples. The DEUF method improved the detection of target indicators and allowed for the detection of pathogens in low concentrations in water after the treatment stages, confirming the suitability of DEUF to concentrate high volumes of different types of water. This method could be useful for microbial analysis in water treatment monitoring and risk assessment, allowing the identification of critical points during the water treatment process and potential hazards in water destined for several uses.
Subject
Subject (English)
Citation
Citation
PASCUAL BENITO, Miriam, et al. Assessment of dead-end ultrafiltration for the detection and quantification of microbial indicators and pathogens in the drinking water treatment processes. International Journal of Hygiene and Environmental Health. 2020. Vol. 230, num. 113628, pags. 1-10. ISSN 1438-4639. [consulted: 17 of June of 2026]. Available at: https://hdl.handle.net/2445/197401