El CRAI romandrà tancat del 24 de desembre de 2025 al 6 de gener de 2026. La validació de documents es reprendrà a partir del 7 de gener de 2026.
El CRAI permanecerá cerrado del 24 de diciembre de 2025 al 6 de enero de 2026. La validación de documentos se reanudará a partir del 7 de enero de 2026.
From 2025-12-24 to 2026-01-06, the CRAI remain closed and the documents will be validated from 2026-01-07.
 

Analysis of corticosteroids in samples of animal origin using QuEChERS and ultrahigh-performance liquid chromatography coupled to high-resolution mass spectrometry.

dc.contributor.authorBeguiristain Seguí, Iñaki
dc.contributor.authorAlongi, Angelina
dc.contributor.authorRúbies Prat, Antoni
dc.contributor.authorGranados i Juan, Mercè
dc.date.accessioned2019-06-14T11:36:11Z
dc.date.available2019-11-26T06:10:16Z
dc.date.issued2018-11-26
dc.date.updated2019-06-14T11:36:11Z
dc.description.abstractA rapid and sensitive method for the confirmatory analysis of 8 synthetic corticosteroids (betamethasone, dexamethasone, prednisolone, 6 methyl prednisolone, triamcinolone, flumethasone, beclomethasone, fluocinolone acetonide) is proposed. The method is useful for detecting illegal treatments in different animal species. It consists of an extraction and clean-up using the Quick Easy Cheap Effective Rugged Safe (QuEChERS) strategy. Quantitative determination is achieved by ultra-high performance liquid chromatography coupled to high-resolution mass spectrometry with heated electrospray ionization in negative mode. Quantification is performed using surrogate matrix matched standard calibration curve with dexamethasone-D4 as the internal standard. The method was validated for analyzing liver samples according to the criteria established by Decision 2002/657/EC. Linearity was assessed in the 1-10 μg kg-1 range and linear correlation coefficients were over 0.99 for all the analytes. CCα ranged from 0.04 to 0.16 μg kg-1 for substances without maximum residue limit. The method allows confident quantification and confirmation of corticosteroids in liver samples, and its simplicity makes it suitable for analyzing large numbers of samples.
dc.format.extent9 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec686311
dc.identifier.issn1618-2642
dc.identifier.urihttps://hdl.handle.net/2445/135119
dc.language.isoeng
dc.publisherSpringer Verlag
dc.relation.isformatofVersió postprint del document publicat a: https://doi.org/10.1007/s00216-018-1459-y
dc.relation.ispartofAnalytical and Bioanalytical Chemistry, 2018, vol. 411, num. 2, p. 449-457
dc.relation.urihttps://doi.org/10.1007/s00216-018-1459-y
dc.rights(c) Springer Verlag, 2018
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.sourceArticles publicats en revistes (Enginyeria Química i Química Analítica)
dc.subject.classificationCromatografia de líquids
dc.subject.classificationEspectrometria de masses
dc.subject.otherLiquid chromatography
dc.subject.otherMass spectrometry
dc.titleAnalysis of corticosteroids in samples of animal origin using QuEChERS and ultrahigh-performance liquid chromatography coupled to high-resolution mass spectrometry.
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/acceptedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
686311.pdf
Mida:
398.55 KB
Format:
Adobe Portable Document Format