Lactate biosensing for reliable on-body sweat analysis

dc.contributor.authorXuan, Xing
dc.contributor.authorPérez Ràfols, Clara
dc.contributor.authorChen, Chen
dc.contributor.authorCuartero, María
dc.contributor.authorCrespo, Gastón A.
dc.date.accessioned2023-02-14T18:17:20Z
dc.date.available2023-02-14T18:17:20Z
dc.date.issued2021-07-06
dc.date.updated2023-02-14T18:17:21Z
dc.description.abstractWearable lactate sensors for sweat analysis are highly appealing for both the sports and healthcare fields. Electrochemical biosensing is the approach most widely used for lactate determination, and this technology generally demonstrates a linear range of response far below the expected lactate levels in sweat together with a high influence of pH and temperature. In this work, we present a novel analytical strategy based on the restriction of the lactate flux that reaches the enzyme lactate oxidase, which is immobilized in the biosensor core. This is accomplished by means of an outer plasticized polymeric layer containing the quaternary salt tetradodecylammonium tetrakis(4-chlorophenyl) borate (traditionally known as ETH500). Also, this layer prevents the enzyme from being in direct contact with the sample, and hence, any influence with the pH and temperature is dramatically reduced. An expanded limit of detection in the millimolar range (from 1 to 50 mM) is demonstrated with this new biosensor, in addition to an acceptable response time; appropriate repeatability, reproducibility, and reversibility (variations lower than 5% for the sensitivity); good resiliency; excellent selectivity; low drift; negligible influence of the flow rate; and extraordinary correlation (Pearson coefficient of 0.97) with a standardized method for lactate detection such as ion chromatography (through analysis of 22 sweat samples collected from 6 different subjects performing cycling or running). The developed lactate biosensor is suitable for on-body sweat lactate monitoring via a microfluidic epidermal patch additionally containing pH and temperature sensors. This applicability was demonstrated in three different body locations (forehead, thigh, and back) in a total of five on-body tests while cycling, achieving appropriate performance and validation. Moreover, the epidermal patch for lactate sensing is convenient for the analysis of sweat stimulated by iontophoresis in the subjects' arm, which is of great potential toward healthcare applications.
dc.format.extent9 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec726628
dc.identifier.issn2379-3694
dc.identifier.urihttps://hdl.handle.net/2445/193624
dc.language.isoeng
dc.publisherAmerican Chemical Society
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.1021/acssensors.1c01009
dc.relation.ispartofACS Sensors, 2021, vol. 6, p. 2763-2771
dc.relation.urihttps://doi.org/10.1021/acssensors.1c01009
dc.rightscc-by (c) Xuan, Xing et al., 2021
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.sourceArticles publicats en revistes (Enginyeria Química i Química Analítica)
dc.subject.classificationElèctrodes
dc.subject.classificationBiotecnologia
dc.subject.classificationBiosensors
dc.subject.otherElectrodes
dc.subject.otherBiotechnology
dc.subject.otherBiosensors
dc.titleLactate biosensing for reliable on-body sweat analysis
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion