Health hazard, cycling and thermal stability as key parameters when selecting a suitable Phase Change Material (PCM)

dc.contributor.authorMiró, Laia
dc.contributor.authorBarreneche, Camila
dc.contributor.authorFerrer, Gerard
dc.contributor.authorSolé, Aran
dc.contributor.authorMartorell, Ingrid
dc.contributor.authorCabeza, Luisa F.
dc.date.accessioned2019-02-19T09:22:05Z
dc.date.available2019-02-19T09:22:05Z
dc.date.issued2016-02-01
dc.date.updated2019-02-19T09:22:05Z
dc.description.abstractFrom the literature review it was observed that there is no stablished methodology, neither a common pattern, when selecting a phase change material for a thermal energy storage application. Melting temperature and enthalpy have traditionally been the considered thermal properties for the material selection. Therefore, the authors of this paper propose a new method of investigation on the suitability of a PCM that takes into account not only thermal properties but also health hazard and both cycling and thermal stability. Health hazard is related with the handling of the material, and both cycling and thermal stabilities with durability. This methodology is applied to five different PCM in the 150-200 °C range: salicylic acid, benzanilide, d-mannitol, hydroquinone, and potassium thiocyanate. Results show that for an application in the 150-200 °C range the suitable PCM are benzanilide and d-mannitol. Moreover, hydroquinone is also suitable but only in closed systems.
dc.format.extent10 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec675269
dc.identifier.issn0040-6031
dc.identifier.urihttps://hdl.handle.net/2445/128402
dc.language.isoeng
dc.publisherElsevier B.V.
dc.relation.isformatofVersió postprint del document publicat a: https://doi.org/10.1016/j.tca.2016.01.014
dc.relation.ispartofThermochimica Acta, 2016, vol. 627-629, p. 39-47
dc.relation.projectIDinfo:eu-repo/grantAgreement/EC/H2020/657466/EU//INPATH-TES
dc.relation.projectIDinfo:eu-repo/grantAgreement/EC/FP7/610692/EU//INNOSTORAGE
dc.relation.urihttps://doi.org/10.1016/j.tca.2016.01.014
dc.rightscc-by-nc-nd (c) Elsevier B.V., 2016
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es
dc.sourceArticles publicats en revistes (Ciència dels Materials i Química Física)
dc.subject.classificationEmmagatzematge d'energia tèrmica
dc.subject.classificationAltes temperatures
dc.subject.otherHeat storage
dc.subject.otherHigh temperatures
dc.titleHealth hazard, cycling and thermal stability as key parameters when selecting a suitable Phase Change Material (PCM)
dc.typeinfo:eu-repo/semantics/article