Amb motiu del tancament d'estiu, la validació de documents es reprendrà a partir del 28 d'agost de 2026. Disculpeu les molèsties.
Con motivo del cierre de verano, la validación de documentos se reanudará a partir del 28 de agosto de 2026. Disculpad las molestias
Due to the summer closure, document validation will resume starting August 28, 2026. We apologize for any inconvenience.

Bioelectronics for Amperometric Biosensors

dc.contributor.authorPunter Villagrasa, Jaime
dc.contributor.authorColomer i Farrarons, Jordi
dc.contributor.authorMiribel-Català, Pere Ll. (Pere Lluís)
dc.date.accessioned2021-06-18T12:36:17Z
dc.date.available2021-06-18T12:36:17Z
dc.date.issued2013-03-13
dc.description.abstractThe Discrete-to-Integrated Electronics group (D2In), at the University of Barcelona, in partnership with the Bioelectronics and Nanobioengineering Group (SICBIO), is researching Smart Self-Powered Bio-Electronic Systems. Our interest is focused on the development of custom built electronic solutions for bio-electronics applications, from discrete devices to Application-specific integrated circuit (ASIC) solutions. The integration of medical and electronic technologies allows the development of biomedical devices able to diagnose and/or treat pathologies by detecting and/or monitoring pathogens, multiple ions, PH changes, and so on. Currently this integration enables advances in various areas such as microelectronics, microfluidics, microsensors and bio-compatible materials which open the door to developing human body Lab-on-a-Chip implantable devices, Pointof- Care in vitro devices, etc. In this chapter the main attention is focused on the design of instrumentation related to amperometrics biosensor: biopotentiostat amplifiers and lock-in amplifiers. A potentiostat is a useful tool in many fields of investigation and industry performing electrochemical trials [1], so the quantity and variety of them is very extensive. Since they can be used in studies and targets as different as the study of chemical metal conversions [2] or carcinogenic cells detection, neuronal activity detection or Deoxyribonucleic acid (DNA) recognition, their characteristics are very varied...ca
dc.format.extent34 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec272104
dc.identifier.urihttps://hdl.handle.net/2445/178594
dc.language.isoengca
dc.publisherIntechOpenca
dc.relation.isformatofReprodució del document publicat a: http://doi.org/10.5772/52248
dc.relation.ispartofChapter 10 in: Rinken, Toonika. 2013. State of the Art in Biosensors. IntechOpen. ISBN: 978-953-51-4253-9 DOI: 10.5772/45832. pp: 241-274.
dc.relation.urihttp://doi.org/10.5772/52248
dc.rightscc by (c) Punter Villagrasa, Jaime et al., 2013
dc.rights.accessRightsinfo:eu-repo/semantics/openAccessca
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.sourceLlibres / Capítols de llibre (Enginyeria Electrònica i Biomèdica)
dc.subject.classificationBiosensorscat
dc.subject.classificationBioelectrònicacat
dc.subject.otherBiosensorseng
dc.subject.otherBioelectronicseng
dc.titleBioelectronics for Amperometric Biosensorsca
dc.typeinfo:eu-repo/semantics/bookPartca
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
272104.pdf
Mida:
1.14 MB
Format:
Adobe Portable Document Format
Descripció: