Improving the Lateral Resolution of Quartz Tuning Fork-Based Sensors in Liquid by Integrating Commercial AFM Tips into the Fiber End

dc.contributor.authorGonzalez Claramonte, Laura
dc.contributor.authorMartínez-Martín, David
dc.contributor.authorOtero Díaz, Jorge
dc.contributor.authorJosé de Pablo, Pedro
dc.contributor.authorPuig i Vidal, Manuel
dc.contributor.authorGómez-Herrero, Julio
dc.date.accessioned2015-09-08T09:59:47Z
dc.date.available2015-09-08T09:59:47Z
dc.date.issued2015-01-14
dc.date.updated2015-09-08T09:59:47Z
dc.description.abstractThe use of quartz tuning fork sensors as probes for scanning probe microscopy is growing in popularity. Working in shear mode, some methods achieve a lateral resolution comparable with that obtained with standard cantilevered probes, but only in experiments conducted in air or vacuum. Here, we report a method to produce and use commercial AFM tips in electrically driven quartz tuning fork sensors operating in shear mode in a liquid environment. The process is based on attaching a standard AFM tip to the end of a fiber probe which has previously been sharpened. Only the end of the probe is immersed in the buffer solution during imaging. The lateral resolution achieved is about 6 times higher than that of the etched microfiber on its own.
dc.format.extent10 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec650690
dc.identifier.issn1424-8220
dc.identifier.pmid25594596
dc.identifier.urihttps://hdl.handle.net/2445/66840
dc.language.isoeng
dc.publisherMDPI
dc.relation.isformatofReproducció del document publicat a: http://dx.doi.org/10.3390/s150101601
dc.relation.ispartofSensors, 2015, vol. 15, p. 1601-1610
dc.relation.urihttp://dx.doi.org/10.3390/s150101601
dc.rightscc-by (c) Gonzalez Claramonte, Laura et al., 2015
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es
dc.sourceArticles publicats en revistes (Enginyeria Electrònica i Biomèdica)
dc.subject.classificationMicroscòpia de força atòmica
dc.subject.classificationMicroscòpia electrònica d'escombratge
dc.subject.otherAtomic force microscopy
dc.subject.otherScanning electron microscopy
dc.titleImproving the Lateral Resolution of Quartz Tuning Fork-Based Sensors in Liquid by Integrating Commercial AFM Tips into the Fiber End
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
650690.pdf
Mida:
3 MB
Format:
Adobe Portable Document Format