Histomorphometric analysis of osseointegrated grade V titanium mini transitional implants inEdentulous mandible by backscattered scanning electron microscopy (BS-SEM)

dc.contributor.authorBeltrán, Víctor
dc.contributor.authorWeber, Benjamín
dc.contributor.authorLillo, Ricardo
dc.contributor.authorManzanares Céspedes, María Cristina
dc.contributor.authorSanzana, Cristina
dc.contributor.authorFuentes, Nicolás
dc.contributor.authorAcuña-Mardones, Pablo
dc.contributor.authorValdivia Gandur, Ivan
dc.date.accessioned2021-03-03T17:15:04Z
dc.date.available2021-03-03T17:15:04Z
dc.date.issued2020-12-22
dc.date.updated2021-03-03T17:15:04Z
dc.description.abstractThe purpose of this study is to assess the use of grade V titanium mini transitional implants(MTIs) immediately loaded by a temporary overdenture. For this, a histomorphometric analysisof the bone area fraction occupancy (BAFO) was performed by backscattered scanning electronmicroscopy (BS-SEM). Four female patients were submitted to surgery in which two MTIs wereinstalled and immediately loaded with a temporary acrylic prosthesis. During the same surgery,two regular diameter implants were placed inside the bone and maintained without mechanical load.After 8 months, the MTIs were extracted using a trephine and processed for ultrastructural boneanalysis by BS-SEM, and the regular-diameter implants were loaded with an overdenture device.A total of 243 BAFOs of MTIs were analyzed, of which 94 were mainly filled with cortical bone,while 149 were mainly filled with trabecular bone. Bone tissue analysis considering the total BAFOswith calcified tissues showed 72.13% lamellar bone, 26.04% woven bone, and 1.82% chondroid bonewithout significant differences between the samples. This study revealed that grade V titanium usedin immediately loaded MTI was successfully osseointegrated by a mature and vascularized bonetissue as assessed from the BAFO.
dc.format.extent8 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec707455
dc.identifier.issn2075-4701
dc.identifier.urihttps://hdl.handle.net/2445/174593
dc.language.isoeng
dc.publisherMDPI
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.3390/met11010002
dc.relation.ispartofMetals, 2020, vol. 11, num. 1, p. 2-9
dc.relation.urihttps://doi.org/10.3390/met11010002
dc.rightscc-by (c) Beltrán, Víctor et al., 2020
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es
dc.sourceArticles publicats en revistes (Patologia i Terapèutica Experimental)
dc.subject.classificationTitani
dc.subject.classificationImplants dentals
dc.subject.classificationElectrons
dc.subject.otherTitanium
dc.subject.otherDental implants
dc.subject.otherElectrones
dc.titleHistomorphometric analysis of osseointegrated grade V titanium mini transitional implants inEdentulous mandible by backscattered scanning electron microscopy (BS-SEM)