Determination of nicotamide in a multivitamin complex by electrochemical-surface enhanced Raman spectroscopy

dc.contributor.authorHernandez, Sheila
dc.contributor.authorPerales-Rondon, Juan V.
dc.contributor.authorArnaiz, Álvaro
dc.contributor.authorPerez-Estebanez, Martín
dc.contributor.authorGómez, Elvira
dc.contributor.authorColina, Álvaro A.
dc.contributor.authorHeras, Aranzazu
dc.date.accessioned2020-10-27T10:14:25Z
dc.date.available2022-10-04T05:10:23Z
dc.date.issued2020-10-04
dc.date.updated2020-10-27T10:14:25Z
dc.description.abstractTime resolved Raman spectroelectrochemistry is a powerful technique to prepare useful Surface Enhanced Raman Scattering (SERS) substrates suitable for quantitative analysis. Moreover, following the evolution of the Raman signal with the applied potential the selection of the best conditions for the analysis is quite simple. In this work, gold SERS substrates are prepared on screen-printed electrodes for the determination of nicotinamide, vitamin B3, in a multivitamin complex. The formation of the substrate has been monitored using UV/Vis absorption spectroelectrochemistry and scanning electron microscopy, which confirmed the generation of gold nanoparticles on the electrode surface. This new method has demonstrated to be suitable for the direct quantification of simple test samples using small sample volumes (50 μL). However, it failed when a complex sample, containing several interfering species, was analysed. A high interference on the preparation of the SERS substrate is observed during the analysis of a multivitamin complex. Despite that, nicotinamide was selectively determined in a multivitamin complex using the method of the standard addition, obtaining remarkable figures of merit (R2=0.99,%RSD<9%).
dc.format.extent22 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec704054
dc.identifier.issn1572-6657
dc.identifier.urihttps://hdl.handle.net/2445/171540
dc.language.isoeng
dc.publisherElsevier B.V.
dc.relation.isformatofVersió postprint del document publicat a: https://doi.org/10.1016/j.jelechem.2020.114743
dc.relation.ispartofJournal of Electroanalytical Chemistry, 2020, vol. 879, p. 114743-114743
dc.relation.urihttps://doi.org/10.1016/j.jelechem.2020.114743
dc.rightscc-by-nc-nd (c) Elsevier B.V., 2020
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es
dc.sourceArticles publicats en revistes (Ciència dels Materials i Química Física)
dc.subject.classificationEspectroscòpia Raman
dc.subject.classificationElectroquímica
dc.subject.classificationVitamines B
dc.subject.otherRaman spectroscopy
dc.subject.otherElectrochemistry
dc.subject.otherVitamin B complex
dc.titleDetermination of nicotamide in a multivitamin complex by electrochemical-surface enhanced Raman spectroscopy
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/acceptedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
704054.pdf
Mida:
882.96 KB
Format:
Adobe Portable Document Format