Solid-phase extraction and field-amplified sample injection-capillary zone electrophoresis for the analysis of benzophenone UV-filters in environmental water samples

dc.contributor.authorPurrà, Miquel
dc.contributor.authorCinca, Roser
dc.contributor.authorLegaz, Jessica
dc.contributor.authorNúñez Burcio, Oscar
dc.date.accessioned2016-05-30T10:45:48Z
dc.date.available2016-05-30T10:45:48Z
dc.date.issued2014-08-22
dc.date.updated2016-05-30T10:45:53Z
dc.description.abstractA field amplified sample injection-capillary zone electrophoresis (FASI-CZE) method for the analysis of benzophenone (BP) UV-filters in environmental water samples was developed, allowing the separation of all compounds in less than 8 minutes. A 9- to 25-fold sensitive enhancement was obtained with FASI-CZE, achieving limits of detection down to 21-59 µg/L for most of the analyzed BPs, with acceptable run-to-run and day-to-day precisions (relative standard deviations lower than 17%). In order to remove water sample salinity and to enhance FASI sensitivity, an off-line solid-phase extraction (SPE) procedure using a Strata X polymeric reversed-phase sorbent was proposed, obtaining recoveries up to 72-90% for most of benzophenones. With the combination of off-line SPE and FASI-CZE, limits of detection in the range 0.06-0.6 µg/L in a river water matrix, representing a 2400- to 6500-fold enhancement, were obtained. Method performance was evaluated by quantifying a blank river water sample spiked at 1 µg/L. For a 95% confidence level, no statistical differences were observed between found concentrations and spiked concentrations (probability at the confidence level, p value, of 0.60), showing that the proposed off-line SPE-FASI-CZE method is suitable for the analysis of benzophenone UV-filters in environmental water samples at low µg/L levels. The method was successfully applied to the analysis of BPs in river water samples collected before and after industrialized and urban areas, and in some drinking water samples.
dc.format.extent14 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec642831
dc.identifier.issn1618-2642
dc.identifier.pmid25146354
dc.identifier.urihttps://hdl.handle.net/2445/99019
dc.language.isoeng
dc.publisherSpringer Verlag
dc.relation.isformatofVersió postprint del document publicat a: http://dx.doi.org/10.1007/s00216-014-8086-z
dc.relation.ispartofAnalytical and Bioanalytical Chemistry, 2014, vol. 406, num. 25, p. 6189-6202
dc.relation.urihttp://dx.doi.org/10.1007/s00216-014-8086-z
dc.rights(c) Springer Verlag, 2014
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.sourceArticles publicats en revistes (Enginyeria Química i Química Analítica)
dc.subject.classificationAnàlisi de l'aigua
dc.subject.classificationElectroforesi capil·lar
dc.subject.otherWater analysis
dc.subject.otherCapillary electrophoresis
dc.titleSolid-phase extraction and field-amplified sample injection-capillary zone electrophoresis for the analysis of benzophenone UV-filters in environmental water samples
dc.typeinfo:eu-repo/semantics/article