Carregant...
Fitxers
Tipus de document
ArticleVersió
Versió acceptadaData de publicació
Llicència de publicació
Si us plau utilitzeu sempre aquest identificador per citar o enllaçar aquest document: https://hdl.handle.net/2445/225914
A novel methodology for the determination of neutral perfluoroalkyl and polyfluoroalkyl substances in water by gas chromatographyatmospheric pressure photoionisation-high resolution mass spectrometry
Títol de la revista
Director/Tutor
ISSN de la revista
Títol del volum
Recurs relacionat
Resum
Here, we developed and validated a new gas chromatography-atmospheric pressure photoionisation high-resolution mass spectrometry (GC-APPI-HRMS) method combined with headspace solid-phase microextraction (HS-SPME) for the determination of neutral perfluoroalkyl and polyfluoroalkyl substances (PFASs) in water samples. The method includes fluorotelomer olefins (FTOs), fluorotelomer alcohols (FTOHs), fluoroctanesulfonamides (FOSAs) and sulfonamido-ethanols (FOSEs). The feasibility of the GC-APPI interface for the ionisation of the target compounds was evaluated, achieving the best results using negative-ion dopant-assisted ionisation with acetone and a source and capillary temperatures of 225 oC and 175 oC, respectively. Under optimal conditions, FTOs and FTOHs mass spectra showed intense in-source CID fragment ions from the fluoroalkyl chain but also the superoxide [M+O2]-· adduct ion. For FOSAs, [M-H]- was the main ion generated, while FOSEs mass spectra showed fragment ions corresponding to the different cleavages of the functional group. The high ionisation efficiency achieved with the GC-APPI interface provided limits of the detection lower than those obtained using traditional GC-MS ionisation techniques, with a high sensitivity, selectivity and precision. For water analysis, a fast and simple HS-SPME procedure was developed, avoiding evaporation steps, which could lead to the loss of the most volatile compounds. The developed HS-SPME GC-APPI-HRMS method showed a good analytical performance for the analysis of river water samples, providing very low limits of detection (0.02e15 ng L 1), good repeatability (RSD < 11%) and trueness (relative error < 12%).
Matèries (anglès)
Citació
Citació
AYALA CABRERA, Juan francisco, CONTRERAS LLIN, Albert, MOYANO MORCILLO, Encarnación, SANTOS VICENTE, Francisco javier. A novel methodology for the determination of neutral perfluoroalkyl and polyfluoroalkyl substances in water by gas chromatographyatmospheric pressure photoionisation-high resolution mass spectrometry. _Analytica Chimica Acta_. 2020. Vol. 1100, núm. 97-106. [consulta: 3 de febrer de 2026]. ISSN: 0003-2670. [Disponible a: https://hdl.handle.net/2445/225914]