Amb motiu del tancament d'estiu, la validació de documents es reprendrà a partir del 28 d'agost de 2026. Disculpeu les molèsties.
Con motivo del cierre de verano, la validación de documentos se reanudará a partir del 28 de agosto de 2026. Disculpad las molestias
Due to the summer closure, document validation will resume starting August 28, 2026. We apologize for any inconvenience.

Antimony nanomaterials modified screen-printed electrodes for the voltammetric determination of metal ions

dc.contributor.authorTapia, María A.
dc.contributor.authorPérez Ràfols, Clara
dc.contributor.authorPastika, Jan
dc.contributor.authorGusmão, Rui Jorge Coelho
dc.contributor.authorSerrano i Plana, Núria
dc.contributor.authorSofer, Zdenek
dc.contributor.authorDíaz Cruz, José Manuel
dc.date.accessioned2022-10-03T14:42:15Z
dc.date.available2022-10-03T14:42:15Z
dc.date.issued2022-06-07
dc.date.updated2022-10-03T14:42:15Z
dc.description.abstractExfoliated β-Sb or two dimensional (2D) antimonene-based modified screen-printed electrode (2D Sb-SPCE), prepared by drop-casting of an exfoliated layered β-antimony (2D Sb) suspension, was used for the simultaneous determination of Pb(II) and Cd(II) by differential pulse anodic stripping voltammetry (DPASV). 2D Sb-SPCE was characterized by microscopic and analytical techniques, and compared not only to bare SPCE but also to layered antimony chalcogenides based-sensors. Both Sb2S3 and Sb2Se3 have an isomorphous tubular one-dimensional (1D) crystal structure, whereas Sb2Te3 and monoelement β-Sb have a 2D layered structure. Under optimized conditions, 2D Sb-SPCE displays an excellent analytical performance with detection limits of 0.3 and 2.7 μg L−1 for Pb(II) and Cd(II), respectively, and a linear response from 1.1 to 128.3 µg L−1 for Pb(II) and from 9.1 to 132.7 µg L−1 for Cd(II). Moreover, 2D Sb-SPCE was successfully applied for the DPASV determination of Pb(II) and Cd(II) in tap water, achieving statistically comparable results to those provided by ICP-MS measurements.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec723833
dc.identifier.issn0013-4686
dc.identifier.urihttps://hdl.handle.net/2445/189556
dc.language.isoeng
dc.publisherElsevier Ltd
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.1016/j.electacta.2022.140690
dc.relation.ispartofElectrochimica Acta, 2022, vol. 425, num. 140690
dc.relation.urihttps://doi.org/10.1016/j.electacta.2022.140690
dc.rightscc-by-nc-nd (c) Tapia, María A. et al., 2022
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.sourceArticles publicats en revistes (Enginyeria Química i Química Analítica)
dc.subject.classificationVoltametria
dc.subject.classificationAntimoni
dc.subject.classificationIons metàl·lics
dc.subject.otherVoltammetry
dc.subject.otherAntimony
dc.subject.otherMetal ions
dc.titleAntimony nanomaterials modified screen-printed electrodes for the voltammetric determination of metal ions
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
723833.pdf
Mida:
3.96 MB
Format:
Adobe Portable Document Format