Migration of antimony from polyethylene terephthalate used in mineral water bottles.

dc.contributor.authorCarneado Moreno, Sergio
dc.contributor.authorHernández-Nataren, E.
dc.contributor.authorLópez Sánchez, José Fermín
dc.contributor.authorSahuquillo Estrugo, Àngels
dc.date.accessioned2014-09-23T07:27:33Z
dc.date.available2014-09-23T07:27:33Z
dc.date.issued2014-06-18
dc.date.updated2014-09-23T07:27:33Z
dc.description.abstractThe influence of storage time and temperature on Sb migration from PET bottles into mineral water was studied in short-term tests lasting up to 15 days and long-term studies lasting up to 220 days. Samples purchased were stored in three different coloured bottles: clear (CL), light blue (LB) and dark blue (DB). Sb migration was assayed by HG-AFS for total determination and HPLC-ICP-MS for speciation analysis. Migration studies showed that waters stored at 4 and 20 oC were not subject to Sb migration. At 40 oC there was a significant increase in Sb concentration, although the maximum limit established by the European Union (5.0 ug/L) was not exceeded, whereas at 60 oC samples were subject to considerable Sb migration after 30 days of storage. In this case, the maximum limit established by the European Union was exceeded and both Sb (V) and Sb (III) were detected.
dc.format.extent29 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec643388
dc.identifier.issn0308-8146
dc.identifier.urihttps://hdl.handle.net/2445/57563
dc.language.isoeng
dc.publisherElsevier B.V.
dc.relation.isformatofVersió postprint del document publicat a: http://dx.doi.org/10.1016/j.foodchem.2014.06.041
dc.relation.ispartofFood Chemistry, 2014, vol. 166, p. 544-550
dc.relation.urihttp://dx.doi.org/10.1016/j.foodchem.2014.06.041
dc.rights(c) Elsevier B.V., 2014
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.sourceArticles publicats en revistes (Enginyeria Química i Química Analítica)
dc.subject.classificationAigües minerals
dc.subject.classificationTereftalat de polietilè
dc.subject.classificationEnvasos
dc.subject.classificationQuímica analítica
dc.subject.classificationSemimetalls
dc.subject.classificationContaminació de l'aigua
dc.subject.otherMineral waters
dc.subject.otherPolyethylene terephthalate
dc.subject.otherContainers
dc.subject.otherAnalytical chemistry
dc.subject.otherSemimetals
dc.subject.otherWater pollution
dc.titleMigration of antimony from polyethylene terephthalate used in mineral water bottles.
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/acceptedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
643388.pdf
Mida:
1.27 MB
Format:
Adobe Portable Document Format