El CRAI romandrà tancat del 24 de desembre de 2025 al 6 de gener de 2026. La validació de documents es reprendrà a partir del 7 de gener de 2026.
El CRAI permanecerá cerrado del 24 de diciembre de 2025 al 6 de enero de 2026. La validación de documentos se reanudará a partir del 7 de enero de 2026.
From 2025-12-24 to 2026-01-06, the CRAI remain closed and the documents will be validated from 2026-01-07.
 
Carregant...
Miniatura

Tipus de document

Article

Versió

Versió acceptada

Data de publicació

Tots els drets reservats

Si us plau utilitzeu sempre aquest identificador per citar o enllaçar aquest document: https://hdl.handle.net/2445/98420

Solid-phase extraction using molecularly imprinted polymer for selective extraction of natural and syntetic estrogens from aqueous samples

Títol de la revista

Director/Tutor

ISSN de la revista

Títol del volum

Resum

A method is proposed for the clean-up and preconcentration of natural and synthetic estrogens from aqueous samples employing molecularly imprinted polymer (MIP) as selective sorbent for solid-phase extraction (SPE). The selectivity of the MIP was checked toward several selected natural and synthetic estrogens such as estrone (E1), 17β-estradiol (β-E2), 17α-estradiol (α-E2), estriol (E3), 17α-ethinylestradiol (EE2), dienestrol (DIES) and diethylstilbestrol (DES). Ultrahigh pressure liquid chromatography (UHPLC) coupled to a TSQ triple quadrupole mass spectrometry (QqQ) was used for analysis of target analytes. The chromatographic separation of the selected compounds was performed in less than 2 min under isocratic conditions. The method was applied to the analysis of estrogens in spiked river and tap water samples. High recoveries (>82%) for estrone, 17β-estradiol, 17α-estradiol, estriol and 17α-ethinylestradiol were obtained. Lower but still satisfactory recoveries (>48%) were achieved for dienestrol and diethylstilbestrol. The method was validated and found to be linear in the range 50-500 ng L-1 with correlation coefficients (R2) greater than 0.995 and repeatability relative standard deviation (RSD) below 8% in all cases. For analysis of 100-ml sample, the method detection limits (LOD) ranged from 4.5 to 9.8 ng L-1 and the limit of quantitation (LOQ) from 14.9 to 32.6 ng L-1. To demonstrate the potential of the MIP obtained, a comparison with commercially available C18 SPE was performed. Molecularly imprinted SPE showed higher recoveries than commercially available C18 SPE for most of the compounds. These results showed the suitability of the MIP-SPE method for the selective extraction of a class of structurally related compounds such as natural and synthetic estrogens.

Citació

Citació

LUCCI, Paolo, NÚÑEZ BURCIO, Oscar, GALCERÁN HUGUET, M. teresa. Solid-phase extraction using molecularly imprinted polymer for selective extraction of natural and syntetic estrogens from aqueous samples. _Journal of Chromatography A_. 2011. Vol. 1218, núm. 30, pàgs. 4828-4833. [consulta: 2 de gener de 2026]. ISSN: 0021-9673. [Disponible a: https://hdl.handle.net/2445/98420]

Exportar metadades

JSON - METS

Compartir registre