Intraamniotic sealing of fetoscopic membrane defects in ex vivo and in vivo sheep models using an integrated semi-rigid bioadhesive patch

dc.contributor.authorMicheletti, Talita
dc.contributor.authorEixarch Roca, Elisenda
dc.contributor.authorFebas, Germán
dc.contributor.authorBerdún Marin, Sergio
dc.contributor.authorParra, Johanna
dc.contributor.authorHernansanz,Albert
dc.contributor.authorBorrós, Salvador
dc.contributor.authorGratacós Solsona, Eduard
dc.date.accessioned2024-06-10T14:21:57Z
dc.date.available2024-06-10T14:21:57Z
dc.date.issued2022-02-07
dc.date.updated2024-06-10T14:22:02Z
dc.description.abstractBackground Preterm prelabor rupture of membranes is the most frequent complication of fetoscopic surgery. Strategies to seal the membrane defect created by fetoscopy have been attempted with little success. We previously developed an integrated semi-rigid bioadhesive patch to seal fetal membrane defects composed of silicone and hydroxypropyl methylcellulose (HPMC) that achieved ex vivo sealing of membrane defects. Objective To evaluate the feasibility of the insertion of our integrated semi-rigid bioadhesive patches using a fetoscopic technique and to test the adhesion in ex vivo human membranes and in vivo ovine model. Study design An experimental study involving two experiments 1) Ex vivo: human fetal membranes were mounted in a custom-designed model with saline solution simulating intraamniotic pressure. The insertion of two different bioadhesive patches made of silicone-HPMC (S-HPMC) and silicone-polyurethane-HPMC (SPU-HPMC) was performed through a 12-Fr cannula mimicking fetoscopic surgery technique. The experiment was repeated 10 times with membranes from different donors. Measures insertion time, successful insertion and adhesion at five minutes. 2) In vivo: 16 patches S-HPMC were inserted by fetoscopy in the amniotic cavity of pregnant sheep (4 bioadhesives per animal, in 4 ewes). Measures successful insertion, adhesion at 5 minutes and adhesion at the end of surgery. Results 1) Ex vivoinsertion study: there was no difference in the insertion time between S-HPMC and SPU-HPMC (p=0.49). Insertion was successful in all cases, but complete adhesion at 5 minutes was superior for S-HPMC (p=0.02). 2) In vivostudy: Insertion of S-HPMC by fetoscopy was feasible and successful in the totality of cases and no complications were reported. Adhesion persisted at 5 minutes and at the end of the surgery in 68.8 and 56.3% of the patches, respectively. Conclusion We describe the feasibility of deploying through a fetoscopic trocar a semi-rigid S-HPMC patch that seals fetal membranes after a fetal invasive procedure. The results warrant further research for improving long-term adhesion and develop a clinically applicable system.
dc.format.extent7 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec719641
dc.identifier.issn0002-9378
dc.identifier.pmid35144009
dc.identifier.urihttps://hdl.handle.net/2445/212785
dc.language.isoeng
dc.publisherElsevier
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.1016/j.ajogmf.2022.100593
dc.relation.ispartofAmerican Journal of Obstetrics and Gynecology, 2022, vol. 4, num.3
dc.relation.urihttps://doi.org/10.1016/j.ajogmf.2022.100593
dc.rightscc-by-nc-nd (c) Micheletti, Talita et al., 2022
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.sourceArticles publicats en revistes (Cirurgia i Especialitats Medicoquirúrgiques)
dc.subject.classificationFetus
dc.subject.classificationCirurgia
dc.subject.classificationLíquid amniòtic
dc.subject.otherFetus
dc.subject.otherSurgery
dc.subject.otherAmniotic liquid
dc.titleIntraamniotic sealing of fetoscopic membrane defects in ex vivo and in vivo sheep models using an integrated semi-rigid bioadhesive patch
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/acceptedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
246821.pdf
Mida:
991.24 KB
Format:
Adobe Portable Document Format