Background: Recent data have shown that short dental implants can be the preferred treatment in most of cases of posterior atrophic alveolar ridges, offering higher survival and lower complication rates than long implants. The survival rates, stability, and marginal bone level changes were compared between short implants (7 and 8.5 mm) and standard-length implants (≥10 mm). Methods: Prospective observational study in which adult patients requiring ≥1 osseointegrated implants to replace missing teeth were recruited consecutively. A clinical examination was performed on the day the definitive prosthesis was placed and after 6 and 12 months. Implant stability quotient (ISQ), marginal bone level (MBL) changes, and the correlation between these parameters and the characteristics of the implants were evaluated. Results: A total of 99 implants were inserted (47 short, 52 standard) in 74 patients. The 12-month survival rate was 100%. ISQ values showed a similar pattern for both types of implants. No correlation was found between ISQ changes after one year and MBL values, nor between the latter and the characteristics of the implants. Conclusions: With clinical treatment criteria, shorter implants (7 and 8.5 mm in length) can be just as useful as standard-length implants in atrophic alveolar ridges, demonstrating similar rates of survival, stability, and crestal bone loss. Keywords: short implants, standard implants, partial edentulism, survival, implant stability, marginal bone level, dental implants

Citació

Citació

Guillermo Pardo-Zamora, ORTIZ-RUÍZ, Antonio josé, CAMACHO-ALONSO, Fabio, MARTÍNEZ-MARCO, José francisco, MOLINA-GONZÁLEZ, Juan manuel, PIQUÉ I CLUSELLA, Núria, VICENTE-HERNÁNDEZ, Ascensión. Short Dental Implants (≤8.5 mm) versus Standard Dental Implants (≥10 mm): A One-Year Post-Loading Prospective Observational Study. _International Journal of Environmental Research and Public Health_. 2021. Vol. 18, núm. 5683. [consulta: 29 de gener de 2026]. ISSN: 1661-7827. [Disponible a: https://hdl.handle.net/2445/181171]

Exportar metadades

JSON - METS

Compartir registre