Enhanced voltammetric determination of metal ions by using a bismuthene-modified screen-printed electrode

dc.contributor.authorTapia, María A.
dc.contributor.authorPérez Ràfols, Clara
dc.contributor.authorGusmão, Rui Jorge Coelho
dc.contributor.authorSerrano i Plana, Núria
dc.contributor.authorSofer, Zdenek
dc.contributor.authorDíaz Cruz, José Manuel
dc.date.accessioned2020-10-07T11:22:17Z
dc.date.available2022-09-22T05:10:23Z
dc.date.issued2020-09-22
dc.date.updated2020-10-07T11:22:18Z
dc.description.abstractA new bismuthene carbon-based screen-printed electrode (2D Bi exf -SPCE) was easily prepared, taking advantage of the strongest features of exfoliated layered bismuth (bismuthene) for metal ions detection by differential pulse anodic stripping voltammetry (DPASV). An exfoliated bismuth suspension was drop- casted on the working electrode surface of a screen-printed carbon electrode (SPCE), giving rise to the 2D Bi exf -SPCE. It was microscopically and analytically examined and compared not only with bare SPCE but also with other bismuth-based screen-printed sensors that report good analytical performance, i.e., bismuth nanoparticle-modified SPCE (BiNP-SPCE) and sputtered bismuth SPE (Bi sp SPE). Under improved conditions and for a 120 s preconcentration time, the sensor exhibits good correlation between peak area and metal concentration in the range 0.2-25.0 μg L −1 for both Pb(II) and Cd(II) with LODs (3 times the standard deviation of the intercept over the slope of the linear calibration curve) of 0.06 and 0.07 μg L −1 for Pb(II) and Cd(II), respectively. 2D Bi exf -SPCE has been successfully applied to a certified estuarine water reference material with excellent trueness and remarkable reproducibility.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec703646
dc.identifier.issn0013-4686
dc.identifier.urihttps://hdl.handle.net/2445/171111
dc.language.isoeng
dc.publisherElsevier Ltd
dc.relation.isformatofVersió postprint del document publicat a: https://doi.org/10.1016/j.electacta.2020.137144
dc.relation.ispartofElectrochimica Acta, 2020, vol. 362, num. 137144
dc.relation.urihttps://doi.org/10.1016/j.electacta.2020.137144
dc.rightscc-by-nc-nd (c) Elsevier Ltd, 2020
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es
dc.sourceArticles publicats en revistes (Enginyeria Química i Química Analítica)
dc.subject.classificationBismut
dc.subject.classificationVoltametria
dc.subject.otherBismuth
dc.subject.otherVoltammetry
dc.titleEnhanced voltammetric determination of metal ions by using a bismuthene-modified screen-printed electrode
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/acceptedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
703646.pdf
Mida:
1.38 MB
Format:
Adobe Portable Document Format