Amb motiu del tancament d'estiu, la validació de documents es reprendrà a partir del 28 d'agost de 2026. Disculpeu les molèsties.
Con motivo del cierre de verano, la validación de documentos se reanudará a partir del 28 de agosto de 2026. Disculpad las molestias
Due to the summer closure, document validation will resume starting August 28, 2026. We apologize for any inconvenience.

Tipus de document

Article

Versió

Versió publicada

Data de publicació

Llicència de publicació

cc-by (c) Tapia, María A. et al., 2023
Si us plau utilitzeu sempre aquest identificador per citar o enllaçar aquest document: https://hdl.handle.net/2445/199325

Antimonene-modified screen-printed carbon nanofibers electrode for enhanced electroanalytical response of metal ions.

Títol de la revista

Director/Tutor

ISSN de la revista

Títol del volum

Resum

A two-dimensional (2D) Sb-modified screen-printed carbon nanofibers electrode (2D Sbexf-SPCNFE) was developed to improve the stripping voltammetric determination of Cd(II) and Pb(II), taking advantage of the synergistic effect between the two nanomaterials. The surface morphology of the 2D Sbexf-SPCNFE was investigated by scanning electron microscopy, energy-dispersive X-ray spectroscopy, and Raman spectroscopy. The analytical performance of 2D Sbexf-SPCNFE was compared to those presented by screen-printed carbon electrodes modified with 2D Sbexf (2D Sbexf-SPCE) and the corresponding bare electrodes: screen-printed carbon nanofibers electrode (SPCNFEbare) and screen-printed carbon electrode (SPCEbare). After optimizing the experimental conditions, the 2D Sbexf-SPCNFE exhibited much better analytical parameters compared to the other assessed sensors. Analysis in 0.01 mol L−1 HCl (pH = 2) using 2D Sbexf-SPCNFE showed excellent linear behavior in the concentration range of 2.9 to 85.0 µg L−1 and 0.3 to 82.0 µg L−1 for Cd(II) and Pb(II), respectively. The limits of detection after 240 s deposition time for Cd(II) and Pb(II) were 0.9 and 0.1 µg L−1, and sensitivities between 1.5 and 3 times higher than those displayed by SPCEbare, SPCNFEbare, and 2D Sbexf-SPCE were obtained. Finally, the 2D Sbexf-SPCNFE was successfully applied to the determination of Cd(II) and Pb(II) traces in a certified estuarine water sample.

Citació

Citació

TAPIA, María A., et al. Antimonene-modified screen-printed carbon nanofibers electrode for enhanced electroanalytical response of metal ions. Chemosensors. 2023. Vol. 11, num. 219. ISSN 2227-9040. [consulted: 18 of August of 2026]. Available at: https://hdl.handle.net/2445/199325

Exportar metadades

JSON - METS

Compartir registre