Calibration transfer in temperature modulated gas sensor arrays

dc.contributor.authorFernández Romero, Luis
dc.contributor.authorGüney, Selda
dc.contributor.authorGutiérrez Gálvez, Agustín
dc.contributor.authorMarco Colás, Santiago
dc.date.accessioned2017-09-04T12:33:02Z
dc.date.available2018-08-31T22:01:23Z
dc.date.issued2016-08-31
dc.date.updated2017-09-04T12:33:02Z
dc.description.abstractShifts in working temperature are an important issue that prevents the successful transfer of calibration models from one chemical instrument to another. This effect is of special relevance when working with gas sensor arrays modulated in temperature. In this paper, we study the use of multivariate techniques to transfer the calibration model from a temperature modulated gas sensor array to another when a global change of temperature occurs. To do so, we built 12 identical master sensor arrays composed of three different types of commercial Figaro sensors and acquired a dataset of sensor responses to three pure substances (ethanol, acetone and butanone) dosed at 7 concentrations. The master arrays are then shifted in temperature (from −50 to 50 °C, ΔT = 10 °C) and considered as slave arrays. Data correction is performed for an increasing number of transfer samples with 4 different calibration transfer techniques: Direct Standardization, Piece-wise Direct Standardization, Orthogonal Signal Correction and Generalized Least Squares Weighting. In order to evaluate the performance of the calibration transfer, we compare the Root Mean Square Error of Prediction (RMSEP) of master and slave arrays, for each instrument correction. Best results are obtained from Piece-wise Direct standardization, which exhibits the lower RMSEP values after correction for the smaller number of transfer samples.
dc.format.extent9 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec660177
dc.identifier.issn0925-4005
dc.identifier.urihttps://hdl.handle.net/2445/114928
dc.language.isoeng
dc.publisherElsevier B.V.
dc.relation.isformatofVersió postprint del document publicat a: https://doi.org/10.1016/j.snb.2016.02.131
dc.relation.ispartofSensors and Actuators B-Chemical, 2016, vol. 231, p. 276-284
dc.relation.urihttps://doi.org/10.1016/j.snb.2016.02.131
dc.rightscc-by-nc-nd (c) Elsevier B.V., 2016
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es
dc.sourceArticles publicats en revistes (Enginyeria Electrònica i Biomèdica)
dc.subject.classificationDetectors de gasos
dc.subject.classificationTemperatura
dc.subject.classificationCalibratge
dc.subject.otherGas detectors
dc.subject.otherTemperature
dc.subject.otherCalibration
dc.titleCalibration transfer in temperature modulated gas sensor arrays