Calculation of portal contribution to hepatic blood flow with 99mTc-microcolloids. A noninvasive method to diagnose liver graft rejection

dc.contributor.authorMartín-Comín, Josep
dc.contributor.authorMora Salvador, Jaume
dc.contributor.authorFigueras Felip, Joan
dc.contributor.authorPuchal Añé, Rafael
dc.contributor.authorJaurrieta Mas, Eduardo
dc.contributor.authorBadosa i Coll, Ferran
dc.contributor.authorRamos Márquez, Miguel
dc.date.accessioned2021-06-15T15:02:19Z
dc.date.available2021-06-15T15:02:19Z
dc.date.issued1988-11-01
dc.date.updated2021-06-15T15:02:19Z
dc.description.abstractThe portal contribution (PC) to hepatic blood flow was calculated in 13 liver graft patients and 13 normal volunteers. The method is based on the quantification and normalization of the liver and spleen activity after the administration of 7 mCi (259 MBq) of 99mTc microcolloid. Forty examinations were performed in liver grafts and 13 in normal subjects. The PC was significantly higher in normal native liver (64.0 +/- 3.0%) than in functioning grafts (58.8 +/- 3.1%). In acutely rejecting patients, PC was significantly lower (52.4 +/- 2.0%) than in functioning grafts and similar to that observed in cholangitis (53.5 +/- 0.7%). The PC increases again once rejection has resolved (57.3 +/- 2.6%). During hepatitis post-transplant PC values (59.7 +/- 3.4%) were similar to those observed in functioning grafts. Overall, PC values over 55% are very unlikely to be due to rejection.
dc.format.extent5 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec064169
dc.identifier.issn0161-5505
dc.identifier.pmid3054017
dc.identifier.urihttps://hdl.handle.net/2445/178417
dc.language.isoeng
dc.publisherThe Society of Nuclear Medicine and Molecular Imaging
dc.relation.isformatofReproducció del document publicat a: https://jnm.snmjournals.org/content/29/11
dc.relation.ispartofJournal of Nuclear Medicine, 1988, vol. 29, num. 11, p. 1776-1780
dc.rights(c) The Society of Nuclear Medicine and Molecular Imaging, 1988
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.sourceArticles publicats en revistes (Ciències Clíniques)
dc.subject.classificationRebuig (Biologia)
dc.subject.classificationFetge
dc.subject.classificationDiagnòstic per la imatge
dc.subject.classificationTecneci
dc.subject.otherGraft rejection
dc.subject.otherLiver
dc.subject.otherDiagnostic imaging
dc.subject.otherTechnetium
dc.titleCalculation of portal contribution to hepatic blood flow with 99mTc-microcolloids. A noninvasive method to diagnose liver graft rejection
dc.typeinfo:eu-repo/semantics/article