Analysis of glycopeptide biomarkers by on-line TiO2 solid-phase extraction capillary electrophoresis-mass spectrometry

dc.contributor.authorMancera Arteu, Montserrat
dc.contributor.authorLleshi, Nejsi
dc.contributor.authorSanz Nebot, María Victoria
dc.contributor.authorGiménez López, Estela
dc.contributor.authorBenavente Moreno, Fernando J. (Julián)
dc.date.accessioned2022-04-08T11:16:11Z
dc.date.available2022-04-08T11:16:11Z
dc.date.issued2020-01-15
dc.date.updated2022-04-08T11:16:11Z
dc.description.abstractIn this study is described an on-line titanium dioxide solid-phase extraction capillary electrophoresis-mass spectrometry (TiO2-SPE-CE-MS) method for the analysis of the glycopeptide glycoforms obtained from the tryptic digests of recombinant human erythropoietin (rhEPO). The O126-glycopeptide of rhEPO was used to optimize the methodology given its importance in quality control of biopharmaceuticals and doping analysis. Several aspects that affect the selective retention and elution, peak efficiency and electrophoretic separation of the O126 glycoforms were investigated to maximize detection sensitivity while minimizing non-specific retention of peptides. Under the optimized conditions, the microcartridge lifetime was around 10 analyses and repeatability was acceptable (%RSD values of 9-11% and 6-11% for migration times and peak areas, respectively). The method was linear between 0.5-50 mg·L-1 and 10-50 mg·L-1 for O126 glycoforms containing NeuAc and NeuGc, respectively, and limits of detection (LODs) were up to 100 times lower than by CE-MS. Although optimized for O-glycopeptides, the method proved also successful for preconcentration of N83-glycopeptides, without compromising the separation between glycopeptide glycoforms with different number of sialic acids. Tryptic digests of other glycoproteins (i.e. human apolipoprotein CIII (APO-C3) and bovine alpha-1-acid glycoprotein (bAGP)) were also analyzed, demonstrating the applicability to glycopeptides with different glycan composition and nature.
dc.format.extent38 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec691980
dc.identifier.issn0039-9140
dc.identifier.pmid31892091
dc.identifier.urihttps://hdl.handle.net/2445/184803
dc.language.isoeng
dc.publisherElsevier B.V.
dc.relation.isformatofVersió postprint del document publicat a: https://doi.org/10.1016/j.talanta.2019.120563
dc.relation.ispartofTalanta, 2020, vol. 209, num. 120563
dc.relation.urihttps://doi.org/10.1016/j.talanta.2019.120563
dc.rightscc-by-nc-nd (c) Elsevier B.V., 2020
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.sourceArticles publicats en revistes (Enginyeria Química i Química Analítica)
dc.subject.classificationDiòxid de titani
dc.subject.classificationEspectrometria de masses
dc.subject.classificationMarcadors bioquímics
dc.subject.classificationElectroforesi capil·lar
dc.subject.classificationGlicoproteïnes
dc.subject.otherTitanium dioxide
dc.subject.otherMass spectrometry
dc.subject.otherBiochemical markers
dc.subject.otherCapillary electrophoresis
dc.subject.otherGlycoproteins
dc.titleAnalysis of glycopeptide biomarkers by on-line TiO2 solid-phase extraction capillary electrophoresis-mass spectrometry
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/acceptedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
691980.pdf
Mida:
802.86 KB
Format:
Adobe Portable Document Format