El Dipòsit Digital ha actualitzat el programari. Contacteu amb dipositdigital@ub.edu per informar de qualsevol incidència.

 

Combining OPM and lesion mapping data for epilepsy surgery planning: a simulation study

dc.contributor.authorThe MELD Project Consortium
dc.contributor.authorBargalló Alabart, Núria​
dc.contributor.authorPascual-Diaz, Saül
dc.contributor.authorGonzález Ortiz, Sofía
dc.contributor.authorConde Blanco, Estefanía
dc.contributor.authorPariente, Jose Carlos
dc.date.accessioned2025-06-12T10:55:33Z
dc.date.available2025-06-12T10:55:33Z
dc.date.issued2024-02-04
dc.date.updated2025-06-12T10:55:33Z
dc.description.abstractWhen planning for epilepsy surgery, multiple potential sites for resection may be identified through anatomical imaging. Magnetoencephalography (MEG) using optically pumped sensors (OP-MEG) is a non-invasive functional neuroimaging technique which could be used to help identify the epileptogenic zone from these candidate regions. Here we test the utility of a-priori information from anatomical imaging for differentiating potential lesion sites with OP-MEG. We investigate a number of scenarios: whether to use rigid or flexible sensor arrays, with or without a-priori source information and with or without source modelling errors. We simulated OP-MEG recordings for 1309 potential lesion sites identified from anatomical images in the Multi-centre Epilepsy Lesion Detection (MELD) project. To localise the simulated data, we used three source inversion schemes: unconstrained, prior source locations at centre of the candidate sites, and prior source locations within a volume around the lesion location. We found that prior knowledge of the candidate lesion zones made the inversion robust to errors in sensor gain, orientation and even location. When the reconstruction was too highly restricted and the source assumptions were inaccurate, the utility of this a-priori information was undermined. Overall, we found that constraining the reconstruction to the region including and around the participant's potential lesion sites provided the best compromise of robustness against modelling or measurement error.
dc.format.extent12 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec756752
dc.identifier.issn2045-2322
dc.identifier.pmid38311614
dc.identifier.urihttps://hdl.handle.net/2445/221510
dc.language.isoeng
dc.publisherNature Publishing Group
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.1038/s41598-024-51857-3
dc.relation.ispartofScientific Reports, 2024, vol. 14, num.1
dc.relation.urihttps://doi.org/10.1038/s41598-024-51857-3
dc.rightscc-by (c) The MELD Project Consortium et al., 2024
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.sourceArticles publicats en revistes (Fonaments Clínics)
dc.subject.classificationSimulació (Ciències de la salut)
dc.subject.classificationCirurgia
dc.subject.classificationEpilèpsia
dc.subject.otherMalingering
dc.subject.otherSurgery
dc.subject.otherEpilepsy
dc.titleCombining OPM and lesion mapping data for epilepsy surgery planning: a simulation study
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
887368.pdf
Mida:
4.09 MB
Format:
Adobe Portable Document Format