On-line aptamer affinity solid-phase extraction direct mass spectrometry for the rapid analysis of α-synuclein in blood
| dc.contributor.author | Salim, Hiba | |
| dc.contributor.author | Pont Villanueva, Laura | |
| dc.contributor.author | Giménez López, Estela | |
| dc.contributor.author | Benavente Moreno, Fernando J. (Julián) | |
| dc.date.accessioned | 2025-03-13T16:52:30Z | |
| dc.date.available | 2025-03-13T16:52:30Z | |
| dc.date.issued | 2023 | |
| dc.date.updated | 2025-03-13T16:52:30Z | |
| dc.description.abstract | On-line aptamer affinity solid-phase extraction direct mass spectrometry (AA-SPE-MS) is presented for the rapid purification, preconcentration, and characterization of α-synuclein (α-syn), which is a protein biomarker related to Parkinson's disease. Valve-free AA-SPE-MS is easily implemented using the typical SPE microcartridges and instrumental set-up necessary for on-line aptamer affinity solid-phase extraction capillary electrophoresis-mass spectrometry (AA-SPE-CE-MS). The essential requirement is substituting the application of the separation voltage by a pressure of 100 mbar for mobilization of the eluted protein through the capillary towards the mass spectrometer. Under optimized conditions with recombinant α-syn, repeatability is good in terms of migration time and peak area (percent relative standard deviation (%RSD) values (n = 3) are 1.3 and 6.6% at 1 μg mL−1, respectively). The method is satisfactorily linear between 0.025 and 5 μg mL−1 (R2 > 0.986), and limit of detection (LOD) is 0.02 μg mL−1 (i.e. 1000, 500, and 10 times lower than by CE-MS, direct MS, and AA-SPE-CE-MS, respectively). The established AA-SPE-MS method is further compared with AA-SPE-CE-MS, including for the analysis of α-syn in blood. The comparison discloses the advantages and disadvantages of AA-SPE-MS for the rapid and sensitive targeted analysis of protein biomarkers in biological fluids. | |
| dc.format.extent | 13 p. | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.idgrec | 738190 | |
| dc.identifier.issn | 0003-2670 | |
| dc.identifier.uri | https://hdl.handle.net/2445/219700 | |
| dc.language.iso | eng | |
| dc.publisher | Elsevier B.V. | |
| dc.relation.isformatof | Versió postprint del document publicat a: https://doi.org/10.1016/j.aca.2023.341149 | |
| dc.relation.ispartof | Analytica Chimica Acta, 2023, vol. 1256, p. 341149 | |
| dc.relation.uri | https://doi.org/10.1016/j.aca.2023.341149 | |
| dc.rights | cc-by-nc-nd (c) Salim, Hiba et al., 2023 | |
| dc.rights.accessRights | info:eu-repo/semantics/openAccess | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
| dc.source | Articles publicats en revistes (Enginyeria Química i Química Analítica) | |
| dc.subject.classification | Malaltia de Parkinson | |
| dc.subject.classification | Purificació | |
| dc.subject.classification | Espectrometria de masses | |
| dc.subject.other | Parkinson's disease | |
| dc.subject.other | Purification | |
| dc.subject.other | Mass spectrometry | |
| dc.title | On-line aptamer affinity solid-phase extraction direct mass spectrometry for the rapid analysis of α-synuclein in blood | |
| dc.type | info:eu-repo/semantics/article | |
| dc.type | info:eu-repo/semantics/publishedVersion |
Fitxers
Paquet original
1 - 1 de 1