Carregant...
Fitxers
Tipus de document
ArticleVersió
Versió publicadaData de publicació
Llicència de publicació
Si us plau utilitzeu sempre aquest identificador per citar o enllaçar aquest document: https://hdl.handle.net/2445/66944
Field-Amplified Sample Injection-Micellar Electrokinetic Chromatography for the Determination of Benzophenones in Food Simulants
Títol de la revista
Director/Tutor
ISSN de la revista
Títol del volum
Recurs relacionat
Resum
A field-amplified sample injection-micellar electrokinetic chromatography (FASI-MEKC) method for the determination of 14 benzophenones (BPs) in a food simulant used in migration studies of food packaging materials was developed, allowing almost baseline separation in less than 21 min. The use of a 10 mM sodium dodecyl sulfate (SDS) solution as sample matrix was mandatory to achieve FASI enhancement of the analyzed BPs. A 21- to 784-fold sensitivity enhancement was achieved with FASI-MEKC, obtaining limits of detection down to 5.1
68.4 µg/L, with acceptable run-to-run precisions (RSD values lower than 22.3%) and accuracy (relative errors lower than 21.0%). Method performance was evaluated by quantifying BPs in the food simulant spiked at 500 µg/L (bellow the established specific migration limit for BP (600 µg/L) by EU legislation). For a 95% confidence level, no statistical differences were observed between found and spiked concentrations (probability at the confidence level, p value, of 0.55), showing that the proposed FASI-MEKC method is suitable for the analysis of BPs in food packaging migration studies at the levels established by EU legislation.
68.4 µg/L, with acceptable run-to-run precisions (RSD values lower than 22.3%) and accuracy (relative errors lower than 21.0%). Method performance was evaluated by quantifying BPs in the food simulant spiked at 500 µg/L (bellow the established specific migration limit for BP (600 µg/L) by EU legislation). For a 95% confidence level, no statistical differences were observed between found and spiked concentrations (probability at the confidence level, p value, of 0.55), showing that the proposed FASI-MEKC method is suitable for the analysis of BPs in food packaging migration studies at the levels established by EU legislation.
Matèries
Matèries (anglès)
Citació
Citació
FÉLEZ, Cristina, MOLET, Anna, NÚÑEZ BURCIO, Oscar. Field-Amplified Sample Injection-Micellar Electrokinetic Chromatography for the Determination of Benzophenones in Food Simulants. _Chromatography_. 2015. Vol. 2(3), núm. 452-471. [consulta: 23 de gener de 2026]. ISSN: 2227-9075. [Disponible a: https://hdl.handle.net/2445/66944]