Sliding window multi-curve resolution: application to gas chromatography - ion mobility spectrometry

dc.contributor.authorOller Moreno, Sergio
dc.contributor.authorSingla Buxarrais, G.
dc.contributor.authorJimenez Soto, J.M.
dc.contributor.authorPardo Martínez, Antonio
dc.contributor.authorGarrido Delgado, R.
dc.contributor.authorArce, Lourdes
dc.contributor.authorMarco Colás, Santiago
dc.date.accessioned2023-04-19T17:32:08Z
dc.date.available2023-04-19T17:32:08Z
dc.date.issued2015-02-24
dc.date.updated2023-04-19T17:32:09Z
dc.description.abstractBlind source separation (BSS) techniques aim to extract a set of source signals from a measured mixture in an unsupervised manner. In the chemical instrumentation domain source signals typically refer to time-varying analyte concentrations, while the measured mixture is the set of observed spectra. Several techniques exist to perform BSS on ion mobility spectrometry, being simple-to-use interactive self-modelling mixture analysis (SIMPLISMA) and multivariate curve resolution (MCR) the most commonly used. The addition of a multi-capillary gas chromatography column using the ion mobility spectrometer as detector has been proposed in the past to increase chemical resolution. Short chromatography times lead to high levels of co-elution, and ion mobility spectra are key to resolve them. For the first time, BSS techniques are used to deconvolve samples of the gas chromatography-ion mobility spectrometry tandem. We propose a method to extract spectra and concentration profiles based on the application of MCR in a sliding window. Our results provide clear concentration profiles and pure spectra, resolving peaks that were not detected by the conventional use of MCR. The proposed technique could also be applied to other hyphenated instruments with similar strong co-elutions.
dc.format.extent9 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec651892
dc.identifier.issn0925-4005
dc.identifier.urihttps://hdl.handle.net/2445/196939
dc.language.isoeng
dc.publisherElsevier B.V.
dc.relation.isformatofVersió postprint del document publicat a: https://doi.org/10.1016/j.snb.2015.02.108
dc.relation.ispartofSensors and Actuators B-Chemical, 2015, vol. 217, p. 13-21
dc.relation.urihttps://doi.org/10.1016/j.snb.2015.02.108
dc.rights(c) Elsevier B.V., 2015
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.sourceArticles publicats en revistes (Enginyeria Electrònica i Biomèdica)
dc.subject.classificationCromatografia de gasos
dc.subject.classificationEspectroscòpia de mobilitat d'ions
dc.subject.classificationOli d'oliva
dc.subject.otherGas chromatography
dc.subject.otherIon mobility spectroscopy
dc.subject.otherOlive oil
dc.titleSliding window multi-curve resolution: application to gas chromatography - ion mobility spectrometry