Feasibility of 4D-Spatio Temporal Image Correlation (STIC) in the Comprehensive Assessment of the Fetal Heart Using FetalHQ®.

dc.contributor.authorNogué i Garrigolas, Laura
dc.contributor.authorMasoller Casas, Narcís
dc.contributor.authorMartínez, Josep Maria
dc.contributor.authorGómez, Olga
dc.contributor.authorGratacós Solsona, Eduard
dc.contributor.authorCrispi Brillas, Fàtima
dc.contributor.authorBennasar Sans, Mª del Mar
dc.contributor.authorIzquierdo, Nora
dc.contributor.authorMula, Cristina
dc.contributor.authorDevore, Greggory
dc.date.accessioned2022-06-21T11:17:47Z
dc.date.available2022-06-21T11:17:47Z
dc.date.issued2022-03-04
dc.description.abstractFetal Heart Quantification (FetalHQ®) is a novel speckle tracking software that permits the study of global and regional ventricular shape and function from a 2D four-chamber-view loop. The 4D-Spatio Temporal Image Correlation (STIC) modality enables the offline analysis of optimized and perfectly aligned cardiac planes. We aimed to evaluate the feasibility and reproducibility of 4D-STIC speckle tracking echocardiography (STE) using FetalHQ® and to compare it to 2D STE. We conducted a prospective study including 31 low-risk singleton pregnancies between 20 and 40 weeks of gestation. Four-chamber view volumes and 2D clips were acquired with an apex pointing at 45° and with a frame rate higher than 60 Hz. Morphometric and functional echocardiography was performed by FetalHQ®. Intra- and interobserver reproducibility were evaluated by the intraclass correlation coefficient (ICC). Our results showed excellent reproducibility (ICC > 0.900) for morphometric evaluation (biventricular area, longitudinal and transverse diameters). Reproducibility was also good (ICC > 0.800) for functional evaluation (biventricular strain, Fractional Area Change, left ventricle volumes, ejection fraction and cardiac output). On the contrary, the study of the sphericity index and shortening fraction of the different ventricular segments showed lower reproducibility (ICC < 0.800). To conclude, 4D-STIC is feasible, reproducible and comparable to 2D echocardiography for the assessment of cardiac morphometry and function.ca
dc.format.extent17 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec729394
dc.identifier.idimarina9300510
dc.identifier.idsira256408
dc.identifier.issn2077-0383
dc.identifier.pmid35268505
dc.identifier.urihttps://hdl.handle.net/2445/186865
dc.language.isoengca
dc.publisherMDPIca
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.3390/jcm11051414
dc.relation.ispartofJournal of Clinical Medicine, 2022, vol. 11, num. 5
dc.relation.urihttps://doi.org/10.3390/jcm11051414
dc.rightscc by (c) Nogué, Laura et al, 2022
dc.rights.accessRightsinfo:eu-repo/semantics/openAccessca
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.sourceArticles publicats en revistes (Cirurgia i Especialitats Medicoquirúrgiques)
dc.subject.classificationElectrocardiografia
dc.subject.classificationFetus
dc.subject.otherElectrocardiography
dc.subject.otherFetus
dc.titleFeasibility of 4D-Spatio Temporal Image Correlation (STIC) in the Comprehensive Assessment of the Fetal Heart Using FetalHQ®.ca
dc.typeinfo:eu-repo/semantics/articleca
dc.typeinfo:eu-repo/semantics/publishedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
22_Nogué_2022.pdf
Mida:
5.64 MB
Format:
Adobe Portable Document Format
Descripció: