Anodic stripping voltammetry with the hanging mercury drop electrode for trace metal detection in soil samples

dc.contributor.authorXu, Kequan
dc.contributor.authorPérez Ràfols, Clara
dc.contributor.authorCuartero, María
dc.contributor.authorCrespo, Gastón A.
dc.date.accessioned2023-03-10T10:05:38Z
dc.date.available2023-03-10T10:05:38Z
dc.date.issued2021-05-13
dc.date.updated2023-03-10T10:05:38Z
dc.description.abstractThe widely spread use of the hanging mercury drop electrode (HMDE) for multi-ion analysis is primarily ascribed to the following reasons: (i) excellent reproducibility owing to the easy renewal of the electrode surface avoiding any hysteresis effect (i.e., a new identical drop is generated for each measurement to be accomplished); (ii) a wide cathodic potential window originating from the passive hydrogen evolution and solvent electrolysis; (iii) the ability to form amalgams with many redox-active metal ions; and (iv) the achievement of (sub)nanomolar limits of detection. On the other hand, the main controversy of the HMDE usage is the high toxicity level of mercury, which has motivated the scientific community to question whether the HMDE deserves to continue being used despite its unique capability for multi-metal detection. In this work, the simultaneous determination of Zn2+, Cd2+, Pb2+, and Cu2+ using the HMDE is investigated as a model system to evaluate the main features of the technique. The analytical benefits of the HMDE in terms of linear range of response, reproducibility, limit of detection, proximity to ideal redox behavior of metal ions and analysis time are herein demonstrated and compared to other electrodes proposed in the literature as less-toxic alternatives to the HMDE. The results have revealed that the HMDE is largely superior to other reported methods in several aspects and, moreover, it displays excellent accuracy when simultaneously analyzing Zn2+, Cd2+, Pb2+, and Cu2+ in such a complex matrix as digested soils. Yet, more efforts are required towards the definitive replacement of the HMDE in the electroanalysis field, despite the elegant approaches already reported in the literature.
dc.format.extent16 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec731067
dc.identifier.issn2227-9040
dc.identifier.urihttps://hdl.handle.net/2445/194984
dc.language.isoeng
dc.publisherMDPI
dc.relation.isformatofReproducció del document publicat a: https://doi.org/10.3390/chemosensors9050107
dc.relation.ispartofChemosensors, 2021, vol. 9, num. 5, p. 107
dc.relation.urihttps://doi.org/10.3390/chemosensors9050107
dc.rightscc-by (c) Xu, Kequan et al., 2021
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.sourceArticles publicats en revistes (Enginyeria Química i Química Analítica)
dc.subject.classificationBioquímica
dc.subject.classificationQuímica
dc.subject.otherBiochemistry
dc.subject.otherChemistry
dc.titleAnodic stripping voltammetry with the hanging mercury drop electrode for trace metal detection in soil samples
dc.typeinfo:eu-repo/semantics/article