Polymeric monolithic microcartridges with gold nanoparticles for the analysis of protein biomarkers by on-line solid-phase extraction capillary electrophoresis-mass spectrometry

dc.contributor.authorPont Villanueva, Laura
dc.contributor.authorMarin, Gemma
dc.contributor.authorVergara-Barberán, Maria
dc.contributor.authorGagliardi, Leonardo G.
dc.contributor.authorSanz Nebot, María Victoria
dc.contributor.authorHerrero-Martínez, J. M.
dc.contributor.authorBenavente Moreno, Fernando J. (Julián)
dc.date.accessioned2020-05-25T09:06:59Z
dc.date.available2022-04-18T05:10:17Z
dc.date.issued2020-04-18
dc.date.updated2020-05-25T09:06:59Z
dc.description.abstractIn this study, polymeric monoliths with gold nanoparticles (AuNP@monolith) were investigated as microcartridges for the analysis of protein biomarkers by on-line solid-phase extraction capillary electrophoresis-mass spectrometry (SPE-CE-MS). "Plug-and-play" microcartridges (7 mm) were prepared from a glycidyl methacrylate (GMA)-based monolithic capillary column (5 cm x 250 µm i.d.), which was modified with ammonia and subsequently functionalized with gold nanoparticles (AuNPs). The performance of these novel microcartridges was evaluated with human transthyretin (TTR), which is a protein related to different types of familial amyloidotic polyneuropathies (FAP). Protein retention depended on the isoelectric point of the protein (TTR pI~5.4) and elution was achieved with a basic phosphate solution. Under the optimized conditions, limits of detection (LODs) for TTR by AuNP@monolith-SPE-CE-MS were 50 times lower than by CE-MS (5 vs 250 mg L−1, with an ion trap (IT) mass spectrometer). The sensitivity enhancement was similar compared to SPE-CE-MS using immunoaffinity (IA) microcartridges with intact antibodies against TTR. Linearity, repeatability in migration times and peak areas, reusability, reproducibility and application to serum samples were also evaluated
dc.format.extent34 p.
dc.format.mimetypeapplication/pdf
dc.identifier.idgrec700994
dc.identifier.issn0021-9673
dc.identifier.urihttps://hdl.handle.net/2445/162210
dc.language.isoeng
dc.publisherElsevier B.V.
dc.relation.isformatofVersió postprint del document publicat a: https://doi.org/10.1016/j.chroma.2020.461097
dc.relation.ispartofJournal of Chromatography A, 2020, vol. 1622, p. 461097-461097
dc.relation.urihttps://doi.org/10.1016/j.chroma.2020.461097
dc.rightscc-by-nc-nd (c) Elsevier B.V., 2020
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/es
dc.sourceArticles publicats en revistes (Enginyeria Química i Química Analítica)
dc.subject.classificationElectroforesi capil·lar
dc.subject.classificationOr
dc.subject.classificationNanopartícules
dc.subject.classificationEspectrometria de masses
dc.subject.otherCapillary electrophoresis
dc.subject.otherGold
dc.subject.otherNanoparticles
dc.subject.otherMass spectrometry
dc.titlePolymeric monolithic microcartridges with gold nanoparticles for the analysis of protein biomarkers by on-line solid-phase extraction capillary electrophoresis-mass spectrometry
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/acceptedVersion

Fitxers

Paquet original

Mostrant 1 - 1 de 1
Carregant...
Miniatura
Nom:
700994.pdf
Mida:
621.73 KB
Format:
Adobe Portable Document Format